Dergi makalesi Açık Erişim

Fluorescence "Turn On-Off" Sensing of Copper (II) Ions Utilizing Coumarin-Based Chemosensor: Experimental Study, Theoretical Calculation, Mineral and Drinking Water Analysis

Arslan, Fatma Nur; Geyik, Gonul Akin; Koran, Kenan; Ozen, Furkan; Aydin, Duygu; Elmas, Sukriye Nihan Karuk; Gorgulu, Ahmet Orhan; Yilmaz, Ibrahim


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/7693</identifier>
  <creators>
    <creator>
      <creatorName>Arslan, Fatma Nur</creatorName>
      <givenName>Fatma Nur</givenName>
      <familyName>Arslan</familyName>
    </creator>
    <creator>
      <creatorName>Geyik, Gonul Akin</creatorName>
      <givenName>Gonul Akin</givenName>
      <familyName>Geyik</familyName>
      <affiliation>Karamanoglu Mehmetbey Univ, Dept Chem, Kamil Ozdag Sci Fac, TR-70100 Karaman 70100, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Koran, Kenan</creatorName>
      <givenName>Kenan</givenName>
      <familyName>Koran</familyName>
      <affiliation>Firat Univ, Sci Fac, Dept Chem, TR-23119 Elazig, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Ozen, Furkan</creatorName>
      <givenName>Furkan</givenName>
      <familyName>Ozen</familyName>
      <affiliation>Akdeniz Univ, Fac Educ, Dept Math &amp; Sci, TR-07058 Antalya, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Aydin, Duygu</creatorName>
      <givenName>Duygu</givenName>
      <familyName>Aydin</familyName>
      <affiliation>Karamanoglu Mehmetbey Univ, Dept Chem, Kamil Ozdag Sci Fac, TR-70100 Karaman 70100, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Elmas, Sukriye Nihan Karuk</creatorName>
      <givenName>Sukriye Nihan Karuk</givenName>
      <familyName>Elmas</familyName>
      <affiliation>Karamanoglu Mehmetbey Univ, Dept Chem, Kamil Ozdag Sci Fac, TR-70100 Karaman 70100, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Gorgulu, Ahmet Orhan</creatorName>
      <givenName>Ahmet Orhan</givenName>
      <familyName>Gorgulu</familyName>
      <affiliation>Firat Univ, Sci Fac, Dept Chem, TR-23119 Elazig, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Yilmaz, Ibrahim</creatorName>
      <givenName>Ibrahim</givenName>
      <familyName>Yilmaz</familyName>
      <affiliation>Karamanoglu Mehmetbey Univ, Dept Chem, Kamil Ozdag Sci Fac, TR-70100 Karaman 70100, Turkey</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Fluorescence "Turn On-Off" Sensing Of Copper (Ii) Ions Utilizing Coumarin-Based Chemosensor: Experimental Study, Theoretical Calculation, Mineral And Drinking Water Analysis</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2020</publicationYear>
  <dates>
    <date dateType="Issued">2020-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/7693</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1007/s10895-020-02503-4</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">Herein, we report the preparation of a fluorescent sensor based on coumarin derivative for copper (II) ion sensing in CH3CN/HEPES media. 6,7-dihydroxy-3-(4-(trifluoro)methylphenyl)coumarin (HMAC) sensor was fabricated and analyzed by spectroscopic techniques. The sensor demonstrates "turn on-off" fluorescence quenching in the presence of copper (II) ions at 458 nm. A clear complex between the chemosensor HMAC and copper (II) ions was characterized by ESI-MS as well as the Job's method. Also, the limit of detection (LOD, 3 sigma/k) value was determined as 24.5 nM in CH3CN/HEPES (95/5, v/v) buffer media (pH = 7.0). This value is lower than the admissible level of copper (II) ions in drinking water (maximum 31.5 mu M) reported by EU Water Framework Directive (WFD) and World Health Organization (WHO) guidelines. The theoretical calculations (density functional theory, DFT) have been performed for the geometric optimized structures. As a final stage, real sample analyses have successfully been performed by using HMAC, as well as ICP-OES method. The relative standard deviation for copper (II) in mineral and drinking water samples has been determined to be below 0.15% and recovery values are in the range of 95.48-109.20%.</description>
  </descriptions>
</resource>
28
4
görüntülenme
indirilme
Görüntülenme 28
İndirme 4
Veri hacmi 1.3 kB
Tekil görüntülenme 25
Tekil indirme 4

Alıntı yap