Dergi makalesi Açık Erişim

Strain sensitivity of steel-fiber-reinforced industrial smart concrete

Demircilioglu, Erman; Teomete, Egemen; Ozbulut, Osman E.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Teomete, Egemen</subfield>
    <subfield code="u">Dokuz Eylul Univ, Dept Civil Engn, Kaynaklar Campus, TR-35160 Izmir, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Ozbulut, Osman E.</subfield>
    <subfield code="u">Univ Virginia, Dept Civil &amp; Environm Engn, Charlottesville, VA USA</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES</subfield>
    <subfield code="v">31</subfield>
    <subfield code="n">1</subfield>
    <subfield code="c">127-136</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1177/1045389X19888722</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Strain sensitivity of steel-fiber-reinforced industrial smart concrete</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Demircilioglu, Erman</subfield>
    <subfield code="u">Dokuz Eylul Univ, Grad Sch Nat &amp; Appl Sci, Izmir, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:6941</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2020-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/6941/files/bib-db0d649c-40f8-43db-bd8c-18c0d5208d78.txt</subfield>
    <subfield code="z">md5:92a5a4107447d59a0520fbd149220a69</subfield>
    <subfield code="s">196</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210315063225.0</controlfield>
  <controlfield tag="001">6941</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Self-sensing cementitious composites can enable structures that are capable of carrying the loads applied on them while monitoring their condition. Most of earlier research has focused on the incorporation of nanofillers or microfibers into cement paste or mortar composites. However, there have been very limited number of studies on the development of steel-fiber-reinforced cementitious composites with self-sensing capabilities. This study explores strain sensitivity of concrete mixtures that include coarse aggregates up to 15 mm diameter and steel fibers with a length of 13 mm and a diameter of 0.25 mm. Five different concrete mixtures with steel fibers at 0%, 0.2%, 0.35%, 0.5%, and 0.8% volume ratios were fabricated. Compression tests with simultaneous measurement of strain and electrical resistance were conducted on the cubic specimens. Gauge factor and percent linearity that is a measure of error in strain sensing were calculated. Concrete mixtures with 0.5% steel fibers possess a strong linear relationship between applied strain and electrical resistance change with a gauge factor over 20 times larger than that of traditional metal strain gauges. Phenomenological models for different resistivity and gauge factors of cement paste/mortar with respect to concrete with large aggregates and short-long fiber cement composites were presented.</subfield>
  </datafield>
</record>
21
4
görüntülenme
indirilme
Görüntülenme 21
İndirme 4
Veri hacmi 784 Bytes
Tekil görüntülenme 20
Tekil indirme 4

Alıntı yap