Experimental investigation of PCM location in a commercial display cabinet cooled by a transcritical CO2 system

Yilmaz, Deniz; Mancuhan, Ebru; Yilmaz, Baris


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Experimental investigation of PCM location in a commercial display cabinet cooled by a transcritical CO2 system</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID</subfield>
    <subfield code="v">120</subfield>
    <subfield code="c">396-405</subfield>
  </datafield>
  <controlfield tag="001">6607</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">In this study, the influence of phase change material (PCM) location in a closed display cabinet cooled by a transcritical CO2 refrigeration system was examined experimentally. Two configurations have been investigated where PCM panels are placed on the backside and the shelves of the cabinet. The effect of PCM locations on the cabinet air temperature and compressor power consumption is evaluated and compared during periods of 24 and 8 h of operation. The variation of in the cabinet air temperatures and power consumption with time is measured during charging, running, and power failure periods. It is found that installing PCMs on the shelves of the cabinet is more advantageous and promising in terms of both maintaining cabinet air temperature homogeneous and keeping it at certain average temperature levels. For PCM on the shelves case, energy saving is found 4.4% less than without PCM case. On the other hand, PCM on the backside case results in 8% more energy consumption. Moreover, the running time is found 15.8 less for PCM on the shelves case. Therefore, PCM on shelves case is concluded to be the best option for PCM utilization in the present study. (C) 2020 Elsevier Ltd and IIR. All rights reserved.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Marmara Univ, Fac Engn, Chem Engn Dept, TR-34722 Istanbul, Turkey</subfield>
    <subfield code="a">Mancuhan, Ebru</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Marmara Univ, Fac Engn, Mech Engn Dept, TR-34722 Istanbul, Turkey</subfield>
    <subfield code="a">Yilmaz, Baris</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="b">article</subfield>
    <subfield code="a">publication</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Istanbul Arel Univ, Mech Engn Dept, Fac Engn &amp; Architecture, TR-34537 Istanbul, Turkey</subfield>
    <subfield code="a">Yilmaz, Deniz</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2020-01-01</subfield>
  </datafield>
  <controlfield tag="005">20210315062759.0</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:6607</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="z">md5:08d8040b1faede3ecff0e5c16c648a66</subfield>
    <subfield code="s">248</subfield>
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/6607/files/bib-fb318dc3-e4d8-4f46-bcaa-54b5a5da2bf1.txt</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1016/j.ijrefrig.2020.09.006</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
</record>
117
6
görüntülenme
indirilme
Görüntülenme 117
İndirme 6
Veri hacmi 1.5 kB
Tekil görüntülenme 115
Tekil indirme 6

Alıntı yap