Konferans bildirisi Açık Erişim

Discrete-Time Integral Sliding Mode Control of a Smart Joint for Minimally Invasive Surgeries

Jabeen, Saher; Yeganeh, Ali Vahid; Simsek, Gorkem Muttalip; Yapici, Guney Guven; Abidi, Khalid; Bebek, Ozkan


Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Jabeen, Saher</dc:creator>
  <dc:creator>Yeganeh, Ali Vahid</dc:creator>
  <dc:creator>Simsek, Gorkem Muttalip</dc:creator>
  <dc:creator>Yapici, Guney Guven</dc:creator>
  <dc:creator>Abidi, Khalid</dc:creator>
  <dc:creator>Bebek, Ozkan</dc:creator>
  <dc:date>2016-01-01</dc:date>
  <dc:description>In this work, a shape memory alloy(SMA) actuator based joint(smart joint) is controlled using a discrete-time integral sliding mode(DISM) control to guide the motion of an active catheter. Controller is designed on the base of a simplified physical model of a single SMA actuator which eliminates the necessity of obtaining an accurate model. SMAs are nonlinear actuators and for this reason, a disturbance observer(DOB) is integrated in to the controller to compensate the model uncertainties and external disturbances to the system. A linearized model is used to design the controller. Bandwidth of SMA actuator is small(response frequency is less than 0.1 Hz) and hardware communication frequency is 20 Hz. Due to high sampling time (tau = 50 ms) it is idealized to design a discretetime controller, as switching frequency of the controller variable is then limited by tau(-1). An experimental setup is designed to test the proposed controller with position feedback. In experimental results, DISM controller with DOB is shown to be robust against system model uncertainties and external disturbances. Different frequency responses are compared and it is shown that the response of 0.04 Hz can be achieved with rms tracking error of 0.0112 radians.</dc:description>
  <dc:identifier>https://aperta.ulakbim.gov.trrecord/54129</dc:identifier>
  <dc:identifier>oai:zenodo.org:54129</dc:identifier>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights>
  <dc:title>Discrete-Time Integral Sliding Mode Control of a Smart Joint for Minimally Invasive Surgeries</dc:title>
  <dc:type>info:eu-repo/semantics/conferencePaper</dc:type>
  <dc:type>publication-conferencepaper</dc:type>
</oai_dc:dc>
30
7
görüntülenme
indirilme
Görüntülenme 30
İndirme 7
Veri hacmi 1.8 kB
Tekil görüntülenme 27
Tekil indirme 7

Alıntı yap