Dergi makalesi Açık Erişim

Decentralized thermal modeling of multi-zone buildings for control applications and investigation of submodeling error propagation

Atam, Ercan


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="c">384-395</subfield>
    <subfield code="p">ENERGY AND BUILDINGS</subfield>
    <subfield code="v">126</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1016/j.enbuild.2016.05.029</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Decentralized thermal modeling of multi-zone buildings for control applications and investigation of submodeling error propagation</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Atam, Ercan</subfield>
    <subfield code="u">Bogazici Univ, Dept Ind Engn, TR-34342 Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:53077</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2016-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/53077/files/bib-572b88cc-0bd3-4f2f-ad03-ad315ef68d69.txt</subfield>
    <subfield code="z">md5:809ea6ae063240b1005edffb36f6b434</subfield>
    <subfield code="s">190</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210315231848.0</controlfield>
  <controlfield tag="001">53077</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Centralized model predictive control is a popular and optimal approach for thermal control of multi-zone buildings. In centralized control of large-scale, multi-zone buildings, decentralized thermal modeling (including identification) may be useful since it may hard and computationally demanding to obtain a single model for the overall system. Success of a centralized predictive controller depends highly on the prediction accuracy of the used control model during control design phase.</subfield>
  </datafield>
</record>
25
5
görüntülenme
indirilme
Görüntülenme 25
İndirme 5
Veri hacmi 950 Bytes
Tekil görüntülenme 22
Tekil indirme 5

Alıntı yap