Dergi makalesi Açık Erişim
Emirhan, E.; Bayrak, A.; Yucel, E. Barlas; Yucel, M.; Ozben, C. S.
{ "conceptrecid": "52916", "created": "2021-03-15T23:16:42.402161+00:00", "doi": "10.1016/j.nima.2016.02.022", "files": [ { "bucket": "bcf2cc7c-f91a-414d-9482-7019ff9e6c55", "checksum": "md5:6b49b48327a583eefad8378fbb333945", "key": "bib-4def9e1b-d4b8-408d-a0f7-6d22112b3507.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/bcf2cc7c-f91a-414d-9482-7019ff9e6c55/bib-4def9e1b-d4b8-408d-a0f7-6d22112b3507.txt" }, "size": 271, "type": "txt" } ], "id": 52917, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1016/j.nima.2016.02.022.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/bcf2cc7c-f91a-414d-9482-7019ff9e6c55", "doi": "https://doi.org/10.1016/j.nima.2016.02.022", "html": "https://aperta.ulakbim.gov.tr/record/52917", "latest": "https://aperta.ulakbim.gov.tr/api/records/52917", "latest_html": "https://aperta.ulakbim.gov.tr/record/52917" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-destekli-proje-yayinlari" } ], "creators": [ { "affiliation": "Istanbul Tech Univ, Fac Sci & Letters, Dept Engn Phys, TR-34469 Istanbul, Turkey", "name": "Emirhan, E." }, { "affiliation": "Istanbul Tech Univ, Fac Sci & Letters, Dept Engn Phys, TR-34469 Istanbul, Turkey", "name": "Bayrak, A." }, { "affiliation": "Istanbul Tech Univ, Fac Sci & Letters, Dept Engn Phys, TR-34469 Istanbul, Turkey", "name": "Yucel, E. Barlas" }, { "affiliation": "Istanbul Tech Univ, Fac Sci & Letters, Dept Engn Phys, TR-34469 Istanbul, Turkey", "name": "Yucel, M." }, { "affiliation": "Istanbul Tech Univ, Fac Sci & Letters, Dept Engn Phys, TR-34469 Istanbul, Turkey", "name": "Ozben, C. S." } ], "description": "A low cost X-ray imaging device based on BPW-34 silicon PIN photodiode was designed and produced. X-rays were produced from a CEI OX/70-P dental tube using a custom made +/- 30 kV power supply. A charge sensitive preamplifier and a shaping amplifier were built for the amplification of small signals produced by photons in the depletion layer of Si-PIN photodiode. A two dimensional position control unit was used for moving the detector in small steps to measure the intensity of X-rays absorbed in the object to be imaged. An Aessent AES220B FPGA module was used for transferring the image data to a computer via USB. Images of various samples were obtained with acceptable image quality despite of the low cost of the device. (C) 2016 Elsevier B.V. All rights reserved.", "doi": "10.1016/j.nima.2016.02.022", "has_grant": false, "journal": { "pages": "1-5", "title": "NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT", "volume": "819" }, "license": { "id": "cc-by" }, "publication_date": "2016-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "52917" }, "parent": { "pid_type": "recid", "pid_value": "52916" } } ] }, "resource_type": { "subtype": "article", "title": "Dergi makalesi", "type": "publication" }, "title": "A low cost X-ray imaging device based on BPW-34 Si-PIN photodiode" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 4.0, "unique_downloads": 4.0, "unique_views": 15.0, "version_downloads": 4.0, "version_unique_downloads": 4.0, "version_unique_views": 15.0, "version_views": 16.0, "version_volume": 1084.0, "views": 16.0, "volume": 1084.0 }, "updated": "2021-03-15T23:16:42.443702+00:00" }
Görüntülenme | 16 |
İndirme | 4 |
Veri hacmi | 1.1 kB |
Tekil görüntülenme | 15 |
Tekil indirme | 4 |