Konferans bildirisi Açık Erişim
Alhan, C.; Guler, E.; Gazi, H.
{
"conceptdoi": "10.81043/aperta.47480",
"conceptrecid": "47480",
"created": "2021-03-15T22:03:20.077390+00:00",
"doi": "10.81043/aperta.47481",
"files": [
{
"bucket": "2ef569e3-366e-414b-b0af-a4aa2ed6fbcc",
"checksum": "md5:7b07671210f5cd9de0824601a747ce5b",
"key": "bib-86b78470-fd88-4a48-9948-4334599f80ef.txt",
"links": {
"self": "https://aperta.ulakbim.gov.tr/api/files/2ef569e3-366e-414b-b0af-a4aa2ed6fbcc/bib-86b78470-fd88-4a48-9948-4334599f80ef.txt"
},
"size": 212,
"type": "txt"
}
],
"id": 47481,
"links": {
"badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.47481.svg",
"bucket": "https://aperta.ulakbim.gov.tr/api/files/2ef569e3-366e-414b-b0af-a4aa2ed6fbcc",
"conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.47480.svg",
"conceptdoi": "https://doi.org/10.81043/aperta.47480",
"doi": "https://doi.org/10.81043/aperta.47481",
"html": "https://aperta.ulakbim.gov.tr/record/47481",
"latest": "https://aperta.ulakbim.gov.tr/api/records/47481",
"latest_html": "https://aperta.ulakbim.gov.tr/record/47481"
},
"metadata": {
"access_right": "open",
"access_right_category": "success",
"communities": [
{
"id": "tubitak-destekli-proje-yayinlari"
}
],
"creators": [
{
"affiliation": "Istanbul Univ, Civil Engn Dept, Istanbul, Turkey",
"name": "Alhan, C."
},
{
"affiliation": "Istanbul Univ, Civil Engn Dept, Istanbul, Turkey",
"name": "Guler, E."
},
{
"affiliation": "Istanbul Univ, Civil Engn Dept, Istanbul, Turkey",
"name": "Gazi, H."
}
],
"description": "Protection of liquid storage tanks from earthquake hazards is vital as damaging of these structures may result in significant economic losses. Base isolation has emerged as a successful alternative to classical earthquake resistant design of liquid storage tanks. However, near-fault earthquake records may include velocity pulses with long periods and large amplitudes that may cause large seismic responses since the isolation periods of base-isolated liquid storage tanks encompass a similar range with pulse periods of near-fault earthquakes. In order to assess the influence of near-fault earthquakes on the seismic response parameters, here, the behavior of a benchmark base-isolated liquid storage tank is evaluated under synthetically generated pulses which represent near-fault earthquakes of different magnitudes recorded at different fault-distances. Seismic response parameters including base and sloshing fluid displacements, isolation system shear, fluid-tank shear force, and fluid shear force are reported in a comparative manner.",
"doi": "10.81043/aperta.47481",
"has_grant": false,
"license": {
"id": "cc-by"
},
"meeting": {
"title": "LIFE-CYCLE OF ENGINEERING SYSTEMS: EMPHASIS ON SUSTAINABLE CIVIL INFRASTRUCTURE"
},
"publication_date": "2017-01-01",
"related_identifiers": [
{
"identifier": "10.81043/aperta.47480",
"relation": "isVersionOf",
"scheme": "doi"
}
],
"relations": {
"version": [
{
"count": 1,
"index": 0,
"is_last": true,
"last_child": {
"pid_type": "recid",
"pid_value": "47481"
},
"parent": {
"pid_type": "recid",
"pid_value": "47480"
}
}
]
},
"resource_type": {
"subtype": "conferencepaper",
"title": "Konferans bildirisi",
"type": "publication"
},
"title": "Behavior of base-isolated liquid storage tanks under synthetic near-fault earthquake pulses"
},
"owners": [
1
],
"revision": 1,
"stats": {
"downloads": 9.0,
"unique_downloads": 9.0,
"unique_views": 49.0,
"version_downloads": 9.0,
"version_unique_downloads": 9.0,
"version_unique_views": 49.0,
"version_views": 51.0,
"version_volume": 1908.0,
"views": 51.0,
"volume": 1908.0
},
"updated": "2021-03-15T22:03:20.123538+00:00"
}
| Görüntülenme | 51 |
| İndirme | 9 |
| Veri hacmi | 1.9 kB |
| Tekil görüntülenme | 49 |
| Tekil indirme | 9 |