Dergi makalesi Açık Erişim

The Determination of Absorption and Reduced Scattering Coefficients of Optical Phantoms Using a Frequency-Domain Multi-Distance Method in a Non-contact Manner

Bal, Ufuk; Utzinger, Urs; Bal, Alkan; Moral, Ozge Taylan


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/4649</identifier>
  <creators>
    <creator>
      <creatorName>Bal, Ufuk</creatorName>
      <givenName>Ufuk</givenName>
      <familyName>Bal</familyName>
      <affiliation>MSKU, Fac Engn Elect &amp; Elect Engn, Mugla, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Utzinger, Urs</creatorName>
      <givenName>Urs</givenName>
      <familyName>Utzinger</familyName>
      <affiliation>Univ Arizona, Biomed Engn, Tucson, AZ 85721 USA</affiliation>
    </creator>
    <creator>
      <creatorName>Bal, Alkan</creatorName>
      <givenName>Alkan</givenName>
      <familyName>Bal</familyName>
      <affiliation>Celal Bayar Univ, Fac Med, Manisa, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Moral, Ozge Taylan</creatorName>
      <givenName>Ozge Taylan</givenName>
      <familyName>Moral</familyName>
      <affiliation>MSKU, Fac Engn Elect &amp; Elect Engn, Mugla, Turkey</affiliation>
    </creator>
  </creators>
  <titles>
    <title>The Determination Of Absorption And Reduced Scattering Coefficients Of Optical Phantoms Using A Frequency-Domain Multi-Distance Method In A Non-Contact Manner</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2020</publicationYear>
  <dates>
    <date dateType="Issued">2020-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/4649</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.4316/AECE.2020.02001</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">A non-contact optical system has been designed to determine the absorption and reduced scattering coefficients of optical phantoms. The frequency-domain multi-distance method, which allows an estimation of optical properties in biological tissue uses the phase and intensity of radio frequency modulated light. The proposed design has been evaluated with optical phantoms. Estimated values for an absorption coefficient equal to 1 cm(-1) are 0.795, 0.690, 0.670 and 0.613 cm(-1) for wavelengths of 658 nm, 705 nm, 785 nm and 833 nm, respectively and for a reduced scattering coefficient equal to 22 cm(-1), the estimated values are 19.876, 18.845, 17.134 and 17.927 cm(-1). It has been concluded that this novel non-contact design can be used to determine the absorption and reduced scattering coefficients of optical phantoms. This system is the first step in medical equipment that may be used to measure absolute quantification of HbO, Hb, HbCO and HbMet concentrations in a contactless manner. Current oximeters with hemoglobin measurement capability require contact between the sensor and the skin. These oximeters have drawbacks when measuring child patients with asthma, bronchiolitis and bronchopneumonia. Currently it is not possible to assess oxygenation in open wounds. Therefore, it is worthwhile to develop a non-contact oximeter.</description>
  </descriptions>
</resource>
22
8
görüntülenme
indirilme
Görüntülenme 22
İndirme 8
Veri hacmi 2.2 kB
Tekil görüntülenme 21
Tekil indirme 7

Alıntı yap