Dergi makalesi Açık Erişim

Effect of pretreatment and membrane orientation on fluxes for concentration of whey with high foulants by using NH3/CO2 in forward osmosis

Seker, M.; Buyuksari, E.; Topcu, S.; Babaoglu, D. S.; Celebi, D.; Keskinler, B.; Aydiner, C.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Buyuksari, E.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Chem Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Topcu, S.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Babaoglu, D. S.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Celebi, D.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Keskinler, B.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Aydiner, C.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="c">237-246</subfield>
    <subfield code="p">BIORESOURCE TECHNOLOGY</subfield>
    <subfield code="v">243</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1016/j.biortech.2017.06.101</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Effect of pretreatment and membrane orientation on fluxes for concentration of whey with high foulants by using NH3/CO2 in forward osmosis</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Seker, M.</subfield>
    <subfield code="u">Gebze Tech Univ, Dept Chem Engn, TR-41400 Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:44415</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2017-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/44415/files/bib-de405956-99fd-4583-8be6-8e1d8c2455ed.txt</subfield>
    <subfield code="z">md5:13d80a00fa533cd69b248a53ba1ca00a</subfield>
    <subfield code="s">282</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210315212105.0</controlfield>
  <controlfield tag="001">44415</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Usage of forward osmosis membrane in FO mode, in which active and support layers of the membrane were in contact with the feed and the draw solutions respectively, provided higher initial water flux (12 L/m(2) h) than the usage of membrane in PRO mode (6 L/m(2) h) having opposite orientation but fluxes approached to each other after 4 h during concentration of whey with NH3/CO2 as draw salt. High organic and inorganic foulants of whey was considered as reason for observed result in addition to lower solute resistivity. Initial water flux (8,5 L/m(2) h) was lower when pre-treatment was applied before forward osmosis process but final flux (4 L/m(2) h) was equal flux of non pre-treatment. Reduction of solute resistivity or absence of hydraulic pressure can be reasons for lower initial flux. Detection of organic carbon but absence of lactose in draw solution showed passage of molecules being different than lactose into draw solution. (C) 2017 Elsevier Ltd. All rights reserved.</subfield>
  </datafield>
</record>
32
7
görüntülenme
indirilme
Görüntülenme 32
İndirme 7
Veri hacmi 2.0 kB
Tekil görüntülenme 27
Tekil indirme 7

Alıntı yap