Dergi makalesi Açık Erişim
Canli, Oltan; Guzel, Baris; Olgun, Elmas Oktem; Cetinturk, Kartal; Uludag, Ismail; Gorhan, Bertan; Dede, Sahan; Ercel, Serife; Karademir, Aykan
<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
<leader>00000nam##2200000uu#4500</leader>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="p">user-tubitak-adresli-yayinlar</subfield>
<subfield code="o">oai:aperta.ulakbim.gov.tr:275507</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a"><p>This paper presents an evaluation of hexabromocyclododecane (HBCD), polybrominated dibenzo-p-dioxins/ furans (PBDD/Fs) and polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) outflows during the destruction of HBCD waste stockpiles in IZAYDAS Hazardous Waste Incinerator (HWI) in Kocaeli, T &amp; uuml;rkiye. HBCD wastes containing 100 % pure HBCD were in 25 kg packages with 63 % Br content were co-incinerated in a 3 -day test burn with average feed rate of 26 kg/h. HBCD, PBDD/Fs and PCDD/Fs were measured in the outlet streams to quantify the amount of unintended POPs releases associated with the processing of HBCD waste and to observe the POP removal performance of air pollution control equipment (APCE) of the incinerator. Total mass outflow rate of HBCDs is calculated as 2.6 g/day, corresponding to destruction efficiency of 99.9996 %. Total toxicity of the brominated dioxins was measured as 0.00044 ng TEQ/Nm 3 on average, while highly brominated congeners are dominant. PCDD/F concentrations in the outflow streams during HBCD test burns are produced similar congener distributions with those given in the previous studies, with the dominance of 7,8 -chlorinated congeners. Mass flows in the outlet streams indicated that the efficiency of ESP and wet scrubbers for the removal of PCDD/Fs and HBCDs. Flue gas concentrations of PCDD/Fs, HBCDs and PBDD/Fs obtained in HBCD burn test indicated that burning HBCD wastes cause no significant emissions as operational parameters and total halogen content in the menu are kept within the incinerator limits.</p></subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">publication</subfield>
<subfield code="b">article</subfield>
</datafield>
<datafield tag="540" ind1=" " ind2=" ">
<subfield code="a">Creative Commons Attribution</subfield>
<subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Canli, Oltan</subfield>
<subfield code="u">TUBITAK Marmara Res Ctr, Climate Change & Sustainabil Vice Presidency, Water Management & Treatment Technol Res Grp, TR-41470 Gebze, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="z">md5:d038636ce78a8d9ba70b423ebfb22593</subfield>
<subfield code="s">400</subfield>
<subfield code="u">https://aperta.ulakbim.gov.trrecord/275507/files/bib-e07173f0-d7ec-4755-b626-1e752109dc6a.txt</subfield>
</datafield>
<controlfield tag="005">20250417122135.0</controlfield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2024-01-01</subfield>
</datafield>
<datafield tag="024" ind1=" " ind2=" ">
<subfield code="a">10.1016/j.scitotenv.2024.172317</subfield>
<subfield code="2">doi</subfield>
</datafield>
<datafield tag="542" ind1=" " ind2=" ">
<subfield code="l">open</subfield>
</datafield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">Evaluation of hexabromocyclododecane (HBCD), polybrominated dibenzo-p-dioxins/furans (PBDD/Fs) and polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) outflows during the destruction of HBCD wastes in a hazardous waste incinerator</subfield>
</datafield>
<datafield tag="909" ind1="C" ind2="4">
<subfield code="v">927</subfield>
<subfield code="c">8</subfield>
<subfield code="p">SCIENCE OF THE TOTAL ENVIRONMENT</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="7">
<subfield code="a">cc-by</subfield>
<subfield code="2">opendefinition.org</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Guzel, Baris</subfield>
<subfield code="u">TUBITAK Marmara Res Ctr, Climate Change & Sustainabil Vice Presidency, Water Management & Treatment Technol Res Grp, TR-41470 Gebze, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Olgun, Elmas Oktem</subfield>
<subfield code="u">TUBITAK Marmara Res Ctr, Climate Change & Sustainabil Vice Presidency, Water Management & Treatment Technol Res Grp, TR-41470 Gebze, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Cetinturk, Kartal</subfield>
<subfield code="u">Istanbul Univ, Inst Marine Sci & Management, TR-34134 Vefa, Istanbul, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Uludag, Ismail</subfield>
<subfield code="u">IZAYDAS Izmit Waste & Residue Treatment Incinerat, Kocaeli Metropolitan Municipal, TR-41310 Izmit, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Gorhan, Bertan</subfield>
<subfield code="u">IZAYDAS Izmit Waste & Residue Treatment Incinerat, Kocaeli Metropolitan Municipal, TR-41310 Izmit, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Dede, Sahan</subfield>
<subfield code="u">IZAYDAS Izmit Waste & Residue Treatment Incinerat, Kocaeli Metropolitan Municipal, TR-41310 Izmit, Kocaeli, Turkiye</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Ercel, Serife</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Karademir, Aykan</subfield>
<subfield code="u">Kocaeli Univ, Fac Engn, Dept Environm Engn, TR-41100 Izmit, Kocaeli, Turkiye</subfield>
</datafield>
<controlfield tag="001">275507</controlfield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-tubitak-adresli-yayinlar</subfield>
</datafield>
</record>
| Görüntülenme | 0 |
| İndirme | 0 |
| Veri hacmi | 0 Bytes |
| Tekil görüntülenme | 0 |
| Tekil indirme | 0 |