Dergi makalesi Açık Erişim

A new system for cuffless blood pressure measurement

Ankishan, H.; Ari, Fikret; Celik, Haydar; Frederick, Blaise B.; Hocke, Lia M.; Erdogan, Sinem Burcu; Unal, Mehmet Altay


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/271676</identifier>
  <creators>
    <creator>
      <creatorName>Ankishan, H.</creatorName>
      <givenName>H.</givenName>
      <familyName>Ankishan</familyName>
      <affiliation>Ankara Univ, Stem Cell Inst, Ankara, Turkiye</affiliation>
    </creator>
    <creator>
      <creatorName>Ari, Fikret</creatorName>
      <givenName>Fikret</givenName>
      <familyName>Ari</familyName>
      <affiliation>Ankara Univ, Elect &amp; Elect Engn, Ankara, Turkiye</affiliation>
    </creator>
    <creator>
      <creatorName>Celik, Haydar</creatorName>
      <givenName>Haydar</givenName>
      <familyName>Celik</familyName>
      <affiliation>Promaxo Inc, Oakland, CA USA</affiliation>
    </creator>
    <creator>
      <creatorName>Frederick, Blaise B.</creatorName>
      <givenName>Blaise B.</givenName>
      <familyName>Frederick</familyName>
      <affiliation>McLean Hosp, McLean Imaging Ctr, Belmont, MA USA</affiliation>
    </creator>
    <creator>
      <creatorName>Hocke, Lia M.</creatorName>
      <givenName>Lia M.</givenName>
      <familyName>Hocke</familyName>
      <affiliation>Harvard Med Sch, Dept Psychiat, Boston, MA USA</affiliation>
    </creator>
    <creator>
      <creatorName>Erdogan, Sinem Burcu</creatorName>
      <givenName>Sinem Burcu</givenName>
      <familyName>Erdogan</familyName>
      <affiliation>Acibadem Univ, Fac Engn &amp; Nat Sci, Istanbul, Turkiye</affiliation>
    </creator>
    <creator>
      <creatorName>Unal, Mehmet Altay</creatorName>
      <givenName>Mehmet Altay</givenName>
      <familyName>Unal</familyName>
      <affiliation>Ankara Univ, Stem Cell Inst, Ankara, Turkiye</affiliation>
    </creator>
  </creators>
  <titles>
    <title>A New System For Cuffless Blood Pressure Measurement</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2023</publicationYear>
  <dates>
    <date dateType="Issued">2023-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/271676</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1016/j.apacoust.2023.109615</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;High blood pressure (HBP) increases the risk of cardiovascular, brain, and renal diseases which can lead to severe illness and death. Due to the variability of BP values at different times during the day, continuous BP measurement would allow more effective early diagnosis of elevated blood pressure, and aid in the management of treatment. Various techniques have been proposed for cuffless BP measurement, often relying on the estimation of pulse transit time (PTT) to infer BP. However, challenges such as computational complexity and limited availability of BP monitoring sensors hinder the reliable and widespread implementation of continuous BP measurement. The proposed wristwatch-based system uses speech sounds together with photoplethysmogram (PPG) and electrocardiogram (ECG) signals, and uses a mathematical model which estimates the systolic BP (SBP) and diastolic BP (DBP) from these inputs. We have obtained Pearson correlation coefficient (PCC)s of 0.6094 for systolic BP and 0.6001 for diastolic BP in these experiments. The mean average errors (MAE) obtained are 8.06 mmHg for systolic BP and 7.48 mmHg for diastolic BP, respectively. This study provides meaningful results based on experimental outputs, demonstrating the feasibility of using speech signals in conjunction with PPG and ECG signals for BP estimation. The simplicity of our mathematical model enables efficient and practical implementation in real-time BP monitoring. As a pilot study, our work establishes a foundation for further research, emphasizing the need for enhancing accuracy and reliability, expanding the dataset, and exploring additional physiological parameters to advance continuous BP estimation. Our findings advance the development of cuffless BP monitoring, and address the computational complexity and real-time processing requirements. Future studies should build upon our work to refine and optimize the proposed approach, ultimately leading to improved continuous BP estimation in diverse populations.&lt;/p&gt;</description>
  </descriptions>
</resource>
1
0
görüntülenme
indirilme
Görüntülenme 1
İndirme 0
Veri hacmi 0 Bytes
Tekil görüntülenme 1
Tekil indirme 0

Alıntı yap