Dergi makalesi Açık Erişim

Evaluation of Different Root Canal Obturation Techniques in Internal Root Resorption of Three-Dimensional Printed Teeth Manufactured Using Computer Software

Ozer, Senem Yigit; Ozkan, Hicran Donmez; Oyucu, Ilayda


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/239536</identifier>
  <creators>
    <creator>
      <creatorName>Ozer, Senem Yigit</creatorName>
      <givenName>Senem Yigit</givenName>
      <familyName>Ozer</familyName>
      <affiliation>Adnan Menderes Univ, Fac Dent, Dept Endodont, TR-09100 Efeler Aydin, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Ozkan, Hicran Donmez</creatorName>
      <givenName>Hicran Donmez</givenName>
      <familyName>Ozkan</familyName>
      <affiliation>Adnan Menderes Univ, Fac Dent, Dept Endodont, TR-09100 Efeler Aydin, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Oyucu, Ilayda</creatorName>
      <givenName>Ilayda</givenName>
      <familyName>Oyucu</familyName>
    </creator>
  </creators>
  <titles>
    <title>Evaluation Of Different Root Canal Obturation Techniques In Internal Root Resorption Of Three-Dimensional Printed Teeth Manufactured Using Computer Software</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2021</publicationYear>
  <dates>
    <date dateType="Issued">2021-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/239536</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1089/3dp.2021.0012</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">The objective of this study was to evaluate and compare the filling ability of various root canal obturation techniques on the internal root resorption (IRR) cavities of replicated tooth samples manufactured using computer software and a three-dimensional (3D) printer. Orthographic images and root structures of a healthy upper maxilla central incisor in determined volumes and sizes were drawn as a prototype with the aid of computer software. Using the same software, an IRR defect was also modeled. These two images were then transferred to the AutoDesk Fusion 360 3D modeling program (AutoDesk, San Rafael, CA) for meshing. Afterward, the tooth model was transferred to a 3D modeling and prototyping program (RhinoCeros 3D; Robert McNells &amp;amp; Assoc., New York) and printed on a 3D printer. Eighty replicas with IRR were manufactured and divided into four groups (n = 20 per group) according to the obturating techniques as follows: Group 1: Cold lateral compaction (CLC), Group 2: Core Carrier System (GuttaCore), Group 3: Injectable Cold Filling (GuttaFlow(R) BioSeal), and Group 4: Continuous Wave Obturation System (Elements Free). After root canal filling, replicas were scanned with a high-resolution micro-computed tomography system (SkyScan 1172; Bruker-microCT, Kontich, Belgium), data regarding voids (unobturated areas) inside the IRR defects were statistically analyzed using nonparametric Kruskal-Wallis tests. A pairwise comparison between the tested groups showed that Groups 3 and 4 had significantly fewer voids compared with Groups 1 and 2 in IRR defects (p &amp;lt; 0.05). Group 1/Group 2 and Group 3/Group 4 had similar results in terms of voids and there were no statistically significant differences (p &amp;gt; 0.05). The injectable cold filling system (GuttaFlow BioSeal) and the injectable continuous wave obturation system (Elements Free) successfully obturated the pathological IRR irregularities when compared with CLC and core carrier (GuttaCore) systems.</description>
  </descriptions>
</resource>
16
7
görüntülenme
indirilme
Görüntülenme 16
İndirme 7
Veri hacmi 1.7 kB
Tekil görüntülenme 15
Tekil indirme 6

Alıntı yap