Dergi makalesi Açık Erişim

Numerical and experimental studies on flow condensation in hydrophilic microtubes

Sadaghiani, Abdolali K.


Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Sadaghiani, Abdolali K.</dc:creator>
  <dc:date>2021-01-01</dc:date>
  <dc:description>Microchannels have increasingly been used to miniaturize heat transfer equipment, improve energy efficiency, and minimize heat transfer fluid inventory. A fundamental understanding of condensation in microscale will yield far-reaching benefits for the different areas of industry. In this study, microtubes with inner diameters of 250, 500, 600, and 900 mu m were used to investigate the effect of microtube diameter, inlet quality, and mass flux on the liquid/vapor interface near the wall boundaries in condensing flow. After validation with the experimental results, a transient numerical model (based on the Volume of Fluid approach) was developed to investigate the hydrothermal properties of condensing such as bubble dynamics, flow map transitions, transient interface shear force, and temperature on flow condensation performance in terms of heat transfer coefficient and pressure drop. The liquid film thickness, slug velocity, and location of transition from annular flow to slug flow inside the microtube were characterized for different microtubes, and the resultant alteration in condensation flow heat transfer and pressure drop is discussed in detail. Using non-dimensional analysis, a flow map was constructed and compared with the available flow maps for flow condensation in microchannels. The obtained results indicated that the interfacial characteristics of condensing flow in microtubes with hydraulic diameters lower than 500 mu m are majorly different from those with D &gt; 500 mu m.</dc:description>
  <dc:identifier>https://aperta.ulakbim.gov.trrecord/238422</dc:identifier>
  <dc:identifier>oai:aperta.ulakbim.gov.tr:238422</dc:identifier>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights>
  <dc:source>APPLIED THERMAL ENGINEERING 197</dc:source>
  <dc:title>Numerical and experimental studies on flow condensation in hydrophilic microtubes</dc:title>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:type>publication-article</dc:type>
</oai_dc:dc>
12
3
görüntülenme
indirilme
Görüntülenme 12
İndirme 3
Veri hacmi 435 Bytes
Tekil görüntülenme 11
Tekil indirme 3

Alıntı yap