Dergi makalesi Açık Erişim

Polymer-based cadmium(II)-selective potentiometric sensors for the analysis of Cd2+ in different environmental samples

Ozbek, Oguz; Isildak, Omer


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY</subfield>
  </datafield>
  <controlfield tag="005">20221007100734.0</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:aperta.ulakbim.gov.tr:238018</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Zonguldak Bulent Ecevit Univ, Sci &amp; Technol Applicat &amp; Res Ctr, Zonguldak, Turkey</subfield>
    <subfield code="a">Ozbek, Oguz</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Ion-selective electrodes or sensors are preferred by researchers in the determination of various ions since they provide very high selectivity and wide concentration range in environmental, industrial, clinical, agricultural, medicinal and routine laboratory analyses. Cadmium, a toxic heavy metal, poses a significant risk to humans and animals due to its wide use in the industry. Today, many analytical methods have been proposed for the determination of cadmium ions in various samples and their working conditions have been determined. One of these methods is potentiometric ion-selective electrodes, which have certain advantages over alternative methods in terms of multiple parameters. In this review, we provide a comprehensive description of the available cadmium(II)-selective polymeric membrane potentiometric sensors and their applications on different environmental samples.</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
  <controlfield tag="001">238018</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Polymer-based cadmium(II)-selective potentiometric sensors for the analysis of Cd2+ in different environmental samples</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2021-01-01</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Tokat Gaziosmanpasa Univ, Fac Sci &amp; Arts, Dept Chem, Tokat, Turkey</subfield>
    <subfield code="a">Isildak, Omer</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/238018/files/bib-c7b1e963-0a09-429d-8b87-5c942a6067fd.txt</subfield>
    <subfield code="s">212</subfield>
    <subfield code="z">md5:1672e2b4c4975c3e6ada2aca12559740</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1080/03067319.2021.1877283</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
</record>
29
5
görüntülenme
indirilme
Görüntülenme 29
İndirme 5
Veri hacmi 1.1 kB
Tekil görüntülenme 28
Tekil indirme 5

Alıntı yap