Dergi makalesi Açık Erişim
Murat, Fahri; Kaymaz, Irfan; Korkmaz, Ismail Hakki
<?xml version='1.0' encoding='UTF-8'?> <record xmlns="http://www.loc.gov/MARC21/slim"> <leader>00000nam##2200000uu#4500</leader> <datafield tag="245" ind1=" " ind2=" "> <subfield code="a">A new porous fixation plate design using the topology optimization</subfield> </datafield> <datafield tag="909" ind1="C" ind2="4"> <subfield code="p">MEDICAL ENGINEERING & PHYSICS</subfield> <subfield code="v">92</subfield> <subfield code="c">18-24</subfield> </datafield> <controlfield tag="001">237698</controlfield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="520" ind1=" " ind2=" "> <subfield code="a">Fixation plates are used to accelerate the biological healing process in the damaged area by providing mechanical stabilization for fractured bones. However, they may cause mechanical and biological complications such as aseptic loosening, stress shielding effect and necrosis during the treatment process. The aim of this study, therefore, was to reduce mechanical and biological complications observed in conventional plate models. For this purpose, an optimum plate geometry was obtained using the finite element based topology optimization approach. An optimum and functionally graded porous model were obtained for the plates used for transverse fractures of diaphysis in long bones. This model was combined with a functional graded porous cage structure, and thus a new generation porous implant model was proposed for fixation plates. In order to determine the performance of the optimum plate model, it was produced by additive manufacturing. Three models; i.e. conventional, optimum and porous fixation plates were statically tested, and they were compared experimentally and numerically using the finite element analysis (FEA). The porous model can be considered as the most suitable option since it requires less invasive inputs, and might lead minimum necrosis formation due to having lesser contact surface with the bone. (c) 2021 IPEM. Published by Elsevier Ltd. All rights reserved.</subfield> </datafield> <datafield tag="650" ind1="1" ind2="7"> <subfield code="2">opendefinition.org</subfield> <subfield code="a">cc-by</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="u">Erzurum Tech Univ, Dept Mech Engn, TR-25050 Erzurum, Turkey</subfield> <subfield code="a">Kaymaz, Irfan</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="u">Erzurum Tech Univ, Dept Mech Engn, TR-25050 Erzurum, Turkey</subfield> <subfield code="a">Korkmaz, Ismail Hakki</subfield> </datafield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="b">article</subfield> <subfield code="a">publication</subfield> </datafield> <datafield tag="542" ind1=" " ind2=" "> <subfield code="l">open</subfield> </datafield> <datafield tag="100" ind1=" " ind2=" "> <subfield code="u">Erzurum Tech Univ, Dept Mech Engn, TR-25050 Erzurum, Turkey</subfield> <subfield code="a">Murat, Fahri</subfield> </datafield> <datafield tag="260" ind1=" " ind2=" "> <subfield code="c">2021-01-01</subfield> </datafield> <controlfield tag="005">20221007100038.0</controlfield> <datafield tag="909" ind1="C" ind2="O"> <subfield code="o">oai:aperta.ulakbim.gov.tr:237698</subfield> <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="856" ind1="4" ind2=" "> <subfield code="z">md5:a08a554c3d2e93c5271a69dc36f80327</subfield> <subfield code="s">159</subfield> <subfield code="u">https://aperta.ulakbim.gov.trrecord/237698/files/bib-aed7d83e-6d73-4387-aaf3-43a256c83387.txt</subfield> </datafield> <datafield tag="540" ind1=" " ind2=" "> <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield> <subfield code="a">Creative Commons Attribution</subfield> </datafield> <datafield tag="024" ind1=" " ind2=" "> <subfield code="a">10.1016/j.medengphy.2021.04.003</subfield> <subfield code="2">doi</subfield> </datafield> </record>
Görüntülenme | 65 |
İndirme | 5 |
Veri hacmi | 795 Bytes |
Tekil görüntülenme | 63 |
Tekil indirme | 5 |