Dergi makalesi Açık Erişim

Polycaprolactone/silk fibroin electrospun nanofibers-based lateral flow test strip for quick and facile determination of bisphenol A in breast milk

Gurel-Gokmen, Begum; Taslak, Hava Dudu; Ozcan, Ozan; Ipar, Necla; Tunali-Akbay, Tugba


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Taslak, Hava Dudu</subfield>
    <subfield code="u">Marmara Univ, Dept Biochem, Fac Dent, Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Ozcan, Ozan</subfield>
    <subfield code="u">Marmara Univ, Dept Biochem, Fac Dent, Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Ipar, Necla</subfield>
    <subfield code="u">Koc Univ Hosp, Dept Pediat, Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Tunali-Akbay, Tugba</subfield>
    <subfield code="u">Marmara Univ, Dept Biochem, Fac Dent, Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS</subfield>
    <subfield code="v">109</subfield>
    <subfield code="n">10</subfield>
    <subfield code="c">1455-1464</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1002/jbm.b.34805</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Polycaprolactone/silk fibroin electrospun nanofibers-based lateral flow test strip for quick and facile determination of bisphenol A in breast milk</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Gurel-Gokmen, Begum</subfield>
    <subfield code="u">Marmara Univ, Dept Biochem, Fac Dent, Istanbul, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:aperta.ulakbim.gov.tr:233304</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2021-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/233304/files/bib-69dcabb7-c5cb-4fc2-b72e-2ed2b4e33db3.txt</subfield>
    <subfield code="z">md5:569cc8aa9bc360e17096e7ebb23c53bb</subfield>
    <subfield code="s">315</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20221007083955.0</controlfield>
  <controlfield tag="001">233304</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This study aimed to develop a sensitive lateral flow test strip for the detection of bisphenol A (BPA) in breast milk. Conventional nitrocellulose test membrane was coated with the coaxial nanofiber, consisting of the inner polycaprolactone (PCL) and the outer PCL/silk fibroin (SF) mixture, to decrease the flow rate of the breast milk in the lateral flow assay (LFA). The nanofiber was prepared by using coaxial electrospinning, and BPA antibody was immobilized physically to the nanofiber. This nanofiber was used as a test membrane in the LFA. Color changes on the test membrane were evaluated as the signal intensity of the BPA. Breast milk creates a background on surfaces due to its structural properties. This background was detected by comparing the signal intensity with the signal intensity of water. The higher signal intensity was found in water samples when compared to breast milk samples. Although the detection limit is 2 ng/ml in both coaxial PCL/SF nanofiber and nitrocellulose (NC) test membranes, the color intensity increased with the increasing BPA concentration in the coaxial PCL/SF nanofiber. As a new dimension, the coaxial PCL/SF nanofiber provided higher color intensity than the NC membrane. In conclusion, a sensitive onsite method was developed for the detection of BPA in breast milk by using new coaxial PCL/SF nanofiber as a test membrane in LFA.</subfield>
  </datafield>
</record>
18
6
görüntülenme
indirilme
Görüntülenme 18
İndirme 6
Veri hacmi 1.9 kB
Tekil görüntülenme 15
Tekil indirme 6

Alıntı yap