Dergi makalesi Açık Erişim

Microcantilever based disposable viscosity sensor for serum and blood plasma measurements

Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Alaca, B. Erdem; Kavakli, Ibrahim Halil; Urey, Hakan


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Microcantilever based disposable viscosity sensor for serum and blood plasma measurements</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">METHODS</subfield>
    <subfield code="v">63</subfield>
    <subfield code="n">3</subfield>
    <subfield code="c">225-232</subfield>
  </datafield>
  <controlfield tag="001">12931</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23 degrees C and 37 degrees C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 mu l and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. (C) 2013 Published by Elsevier Inc.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Elbuken, Caglar</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Ermek, Erhan</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Mostafazadeh, Aref</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, Dept Mol Biol &amp; Genet, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Baris, Ibrahim</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Alaca, B. Erdem</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Kavakli, Ibrahim Halil</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Urey, Hakan</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="b">article</subfield>
    <subfield code="a">publication</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Koc Univ, TR-34450 Istanbul, Turkey</subfield>
    <subfield code="a">Cakmak, Onur</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2013-01-01</subfield>
  </datafield>
  <controlfield tag="005">20210315075950.0</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:12931</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="z">md5:254212b7585948a04c24a4463b956c2d</subfield>
    <subfield code="s">222</subfield>
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/12931/files/bib-d4d9e20d-5c2c-40d0-a40b-f55d1d995977.txt</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1016/j.ymeth.2013.07.009</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
</record>
34
5
görüntülenme
indirilme
Görüntülenme 34
İndirme 5
Veri hacmi 1.1 kB
Tekil görüntülenme 34
Tekil indirme 5

Alıntı yap