Dergi makalesi Açık Erişim
Diril, A.; Bourson, F.; Parga, C.; Sadli, M.
{
"conceptrecid": "100540",
"created": "2021-03-16T14:27:49.287944+00:00",
"doi": "10.1007/s10765-015-1971-7",
"files": [
{
"bucket": "da1cac21-ca03-488d-9a3f-08d1caddfc44",
"checksum": "md5:1f1bc66b02346b64226bb96e310d4f94",
"key": "bib-f4f7268b-4b5e-4f6c-acea-1b58e0376260.txt",
"links": {
"self": "https://aperta.ulakbim.gov.tr/api/files/da1cac21-ca03-488d-9a3f-08d1caddfc44/bib-f4f7268b-4b5e-4f6c-acea-1b58e0376260.txt"
},
"size": 206,
"type": "txt"
}
],
"id": 100541,
"links": {
"badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1007/s10765-015-1971-7.svg",
"bucket": "https://aperta.ulakbim.gov.tr/api/files/da1cac21-ca03-488d-9a3f-08d1caddfc44",
"doi": "https://doi.org/10.1007/s10765-015-1971-7",
"html": "https://aperta.ulakbim.gov.tr/record/100541",
"latest": "https://aperta.ulakbim.gov.tr/api/records/100541",
"latest_html": "https://aperta.ulakbim.gov.tr/record/100541"
},
"metadata": {
"access_right": "open",
"access_right_category": "success",
"communities": [
{
"id": "tubitak-adresli-yayinlar"
}
],
"creators": [
{
"affiliation": "TUBITAK Ulusal Metrol Enstitusu TUBITAK UME, Kocaeli, Turkey",
"name": "Diril, A."
},
{
"affiliation": "Lab Commun Metrol LNE Cnam, Paris, France",
"name": "Bourson, F."
},
{
"name": "Parga, C."
},
{
"affiliation": "Lab Commun Metrol LNE Cnam, Paris, France",
"name": "Sadli, M."
}
],
"description": "High-temperature eutectic fixed points have proved to be convenient tools for temperature scale dissemination and thermometer calibrations/checks at temperatures above . In order to investigate the feasibility of metal-carbon eutectic cells in industrial applications as a means for assessing the traceability of non-contact thermometers, a batch of cells was constructed at LNE-Cnam, NPL, and TUBITAK UME. Compared to the usual dimensions of high-temperature fixed point cells (45 mm in length 24 mm in diameter), a new cell design was created to fit with industrial applications. TUBITAK UME constructed and characterized five ruthenium-carbon (Ru-C) eutectic cells of dimensions 24 mm in length 24 mm in diameter. One of these cells has been selected and characterized at CEA premises. Ru-C eutectic cells have been evaluated in terms of short-term repeatability, reproducibility, furnace effect, sharp temperature ramps, and the effect of cell location. Measurements at TBA degrees TAK UME have been performed with a transfer standard pyrometer calibrated at the copper point and a BB3500pg high-temperature blackbody furnace was used for construction and measurement. For the measurements at CEA, a Land Standard-HIMERT S1 radiation thermometer and a VITI induction furnace were used. In this article results of the measurements at TBA degrees TAK UME and CEA will be presented. The possible use of these mini-eutectic cells as industrial temperature standards will be discussed.",
"doi": "10.1007/s10765-015-1971-7",
"has_grant": false,
"journal": {
"issue": "12",
"pages": "3355-3365",
"title": "INTERNATIONAL JOURNAL OF THERMOPHYSICS",
"volume": "36"
},
"license": {
"id": "cc-by"
},
"publication_date": "2015-01-01",
"relations": {
"version": [
{
"count": 1,
"index": 0,
"is_last": true,
"last_child": {
"pid_type": "recid",
"pid_value": "100541"
},
"parent": {
"pid_type": "recid",
"pid_value": "100540"
}
}
]
},
"resource_type": {
"subtype": "article",
"title": "Dergi makalesi",
"type": "publication"
},
"title": "Construction and Characterization of Mini-ruthenium-Carbon Eutectic Cells for Industrial Use"
},
"owners": [
1
],
"revision": 1,
"stats": {
"downloads": 5.0,
"unique_downloads": 5.0,
"unique_views": 21.0,
"version_downloads": 5.0,
"version_unique_downloads": 5.0,
"version_unique_views": 21.0,
"version_views": 22.0,
"version_volume": 1030.0,
"views": 22.0,
"volume": 1030.0
},
"updated": "2021-03-16T14:27:49.334979+00:00"
}
| Görüntülenme | 22 |
| İndirme | 5 |
| Veri hacmi | 1.0 kB |
| Tekil görüntülenme | 21 |
| Tekil indirme | 5 |