Konferans bildirisi Açık Erişim
Eryurek, Mustafa; Karadag, Yasin; Tasaltin, Nevin; Kilinc, Necmettin; Kiraz, Alper
{ "conceptrecid": "100316", "created": "2021-03-16T14:24:46.645914+00:00", "doi": "10.1117/12.2078244", "files": [ { "bucket": "714eec4d-22a3-4a25-9c16-68dc924472de", "checksum": "md5:04c9a46152a637006c75a88a9d5c2477", "key": "bib-c821ccf2-bf3d-41ec-9589-6fe455b2474a.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/714eec4d-22a3-4a25-9c16-68dc924472de/bib-c821ccf2-bf3d-41ec-9589-6fe455b2474a.txt" }, "size": 198, "type": "txt" } ], "id": 100317, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1117/12.2078244.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/714eec4d-22a3-4a25-9c16-68dc924472de", "doi": "https://doi.org/10.1117/12.2078244", "html": "https://aperta.ulakbim.gov.tr/record/100317", "latest": "https://aperta.ulakbim.gov.tr/api/records/100317", "latest_html": "https://aperta.ulakbim.gov.tr/record/100317" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-adresli-yayinlar" } ], "creators": [ { "affiliation": "Koc Univ, Dept Phys, TR-34450 Istanbul, Turkey", "name": "Eryurek, Mustafa" }, { "affiliation": "Marmara Univ, Dept Phys, TR-34722 Istanbul, Turkey", "name": "Karadag, Yasin" }, { "affiliation": "TUBITAK MRC Mat Inst, Sensor Mat Photon Technol Lab, TR-41470 Gebze, Kocaeli, Turkey", "name": "Tasaltin, Nevin" }, { "affiliation": "Nigde Univ, Mechatron Engn Dept, TR-51245 Nigde, Turkey", "name": "Kilinc, Necmettin" }, { "name": "Kiraz, Alper" } ], "description": "An SU-8 polymer microdisk resonator coated with a palladium (Pd) layer and coupled to a single-mode optical waveguide is used to as a hydrogen (H-2) gas sensor. In the presence of H2 a red shift is observed in the spectral positions of the microdisk whispering gallery modes (WGMs) due to the expansion in the Pd lattice. H-2 concentrations below the flammable limit (4%) down to 0.3% could be detected in nitrogen atmosphere at room temperature. For H-2 concentrations between 0.3 1%, WGM spectral positions shifted linearly with H-2 concentration at a rate of 32 pm/%H-2. Average response time of the devices was measured to be 50 s for 1% H-2. The proposed device concept can also be used to detect different chemical gases by using appropriate sensing layers.", "doi": "10.1117/12.2078244", "has_grant": false, "license": { "id": "cc-by" }, "meeting": { "title": "LASER RESONATORS, MICRORESONATORS, AND BEAM CONTROL XVII" }, "publication_date": "2015-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "100317" }, "parent": { "pid_type": "recid", "pid_value": "100316" } } ] }, "resource_type": { "subtype": "conferencepaper", "title": "Konferans bildirisi", "type": "publication" }, "title": "Hydrogen gas sensing using palladium-coated microdisk microresonators" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 8.0, "unique_downloads": 8.0, "unique_views": 19.0, "version_downloads": 8.0, "version_unique_downloads": 8.0, "version_unique_views": 20.0, "version_views": 20.0, "version_volume": 1584.0, "views": 19.0, "volume": 1584.0 }, "updated": "2021-03-16T14:24:46.694460+00:00" }
Görüntülenme | 19 |
İndirme | 8 |
Veri hacmi | 1.6 kB |
Tekil görüntülenme | 19 |
Tekil indirme | 8 |