Dergi makalesi Açık Erişim

Effects of Waveform Model on Sensitivity Values of Transducers Used in Mechanical Dynamic Measurements

Bilgic, E.; Durgut, Y.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Durgut, Y.</subfield>
    <subfield code="u">TUBITAK Ulusal Metrol Enstitusu, Pressure Lab, Gebze, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">ACTA PHYSICA POLONICA A</subfield>
    <subfield code="v">128</subfield>
    <subfield code="n">2B</subfield>
    <subfield code="c">B267-B270</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.12693/APhysPolA.128.B-267</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Effects of Waveform Model on Sensitivity Values of Transducers Used in Mechanical Dynamic Measurements</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Bilgic, E.</subfield>
    <subfield code="u">TUBITAK Ulusal Metrol Enstitusu, Acoust Lab, Gebze, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:100301</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2015-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/100301/files/10-12693-aphyspola-128-b-267.pdf</subfield>
    <subfield code="z">md5:c69e6057b19fa52f8ca03812b0345935</subfield>
    <subfield code="s">468795</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210316142433.0</controlfield>
  <controlfield tag="001">100301</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Dynamic calibration of the pressure transducers and accelerometers are carried out by applying dynamic mechanical inputs to them. Determination of those transducers' sensitivities, defined as the ratio of electrical output of the transducer to the mechanical input, is an important task for calibration laboratories. Data obtained during calibration are processed in order to have the peak values of the input and output signals which are sampled by data acquisition boards. Different approximations are made such as fitting the data in the range of 90% of the maximum value for parabola or half-sine waveform. It is clear that waveform model used and also the resolution and the sampling rate of the data acquisition boards have effects on the accuracy of the sensitivity of the transducer. For the investigation, the electrical output signal of the transducer corresponding to the mechanical input is recorded and simulated with different resolutions and sampling rates. Those data are processed for the waveforms of half-sine, parabola, Gaussian distribution. The effect of the waveform model of the input quantities on the dynamic sensitivity is discussed in this paper.</subfield>
  </datafield>
</record>
40
36
görüntülenme
indirilme
Görüntülenme 40
İndirme 36
Veri hacmi 16.9 MB
Tekil görüntülenme 39
Tekil indirme 35

Alıntı yap