Published January 1, 2018
| Version v1
Conference paper
Open
A 10-GSamples/s Track and Hold Amplifier Using Reference Current Source Unaffected by Temperature in 0.18 mu m SiGe BiCMOS Technology
Creators
- 1. TUBITAK BILGEM, Kocaeli, Turkey
- 2. Abant Izzet Baysal Univ, Dept Elect & Elect Engn, Bolu, Turkey
Description
This paper presents design and simulation of a track and hold amplifier(THA) and a temperature independent reference current circuit for high speed analog digital converter in 0.18 mu m SiGe BiCMOS process BCS180G of HHNEC. The THAs circuit is based on the switched emitter follower topology. Therewithal, the reference current source circuit consists of a proportional to absolute temperature(PTAT) and complementary to absolute temperature(CTAT) circuits. The reference current source unaffected by temperature is working with an accuracy of %0.4 between -45 degrees C and 120 degrees C. Respectively, the power supply voltage of the designed THAs circuits and temperature independent reference current circuit is 5V and 3.3V. The active layout area of designed circuit is 0.02534mm(2)(132 mu m x 192 mu m), consuming 465mW at 10GS/s sampling rate.
Files
bib-2ebbfe7e-1d8a-4683-bdd9-57a32ba16498.txt
Files
(247 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:b5b302254d57c328213ed031c7237f2a
|
247 Bytes | Preview Download |