TUBITAK UME, national metrology institute of Turkey, established a new voltage quantum standard based on programmable 10 V Josephson array operated in the liquid helium. System is very compact, able to produce reference dc voltage up to 10 V and ac voltages up to 7 V rms at several kHz, and can be easily integrated to any custom application.