Establishment of Reference Power Standard at SASO NMCC and GULFMET Bilateral Comparison
- 1. Natl Measurement & Calibrat Ctr, POB 3437, Riyadh 11471, Saudi Arabia
- 2. TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey
Description
A well-known 3458A based digital sampling wattmeter was established for power and harmonics measurements at SASO NMCC. Its compact design and synchronized to the power source makes the standard unique for the calibrations needed by nationwide laboratories and industry. 40 ppm and 200 ppm are the first estimations in measurement uncertainties for power and harmonics, respectively. And, the first power comparison was organized under GULFMET.EM-S2 in order to evaluate the performance of the standard.