Published January 1, 2012
| Version v1
Journal article
Open
Pseudo Dynamic Testing of an RC Frame Retrofitted with Chevron Braces
Creators
- 1. Akdeniz Univ, Dept Civil Engn, TR-07058 Antalya, Turkey
- 2. Middle E Tech Univ, Dept Civil Engn, TR-06531 Ankara, Turkey
Description
Two-story three-bay reinforced concrete frames with and without chevron brace was tested using pseudo dynamic test method. The chevron braces were implemented to the interior span of the RC frame. Chevron-braced frame was observed to be effective to control inter-story drift demands. Based on the observed damage state and dynamic response of the test frames, performance states were discussed for different scales of Duzce ground motions. The test results were compared with the results of the nonlinear time history analysis. The analysis results were capable of estimating the base shear capacity and displacement demands with a reasonable accuracy.
Files
bib-57759e1e-d55a-4377-88f8-fb494e1c7393.txt
Files
(164 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:513cf35bd66a35d12a7664da67996111
|
164 Bytes | Preview Download |