Published January 1, 2012 | Version v1
Journal article Open

Pseudo Dynamic Testing of an RC Frame Retrofitted with Chevron Braces

  • 1. Akdeniz Univ, Dept Civil Engn, TR-07058 Antalya, Turkey
  • 2. Middle E Tech Univ, Dept Civil Engn, TR-06531 Ankara, Turkey

Description

Two-story three-bay reinforced concrete frames with and without chevron brace was tested using pseudo dynamic test method. The chevron braces were implemented to the interior span of the RC frame. Chevron-braced frame was observed to be effective to control inter-story drift demands. Based on the observed damage state and dynamic response of the test frames, performance states were discussed for different scales of Duzce ground motions. The test results were compared with the results of the nonlinear time history analysis. The analysis results were capable of estimating the base shear capacity and displacement demands with a reasonable accuracy.