Published January 1, 2012
| Version v1
Journal article
Open
A Urinary Bcl-2 Surface Acoustic Wave Biosensor for Early Ovarian Cancer Detection
- 1. Univ S Florida, Dept Mech Engn, Tampa, FL 33620 USA
- 2. Univ S Florida Hlth, Dept Pathol & Cell Biol, Tampa, FL 33612 USA
Description
In this study, the design, fabrication, surface functionalization and experimental characterization of an ultrasonic MEMS biosensor for urinary anti-apoptotic protein B-cell lymphoma 2 (Bcl-2) detection with sub ng/mL sensitivity is presented. It was previously shown that urinary Bcl-2 levels are reliably elevated during early and late stages of ovarian cancer. Our biosensor uses shear horizontal (SH) surface acoustic waves (SAWs) on surface functionalized ST-cut Quartz to quantify the mass loading change by protein adhesion to the delay path. SH-SAWs were generated and received by a pair of micro-fabricated interdigital transducers (IDTs) separated by a judiciously designed delay path. The delay path was surface-functionalized with monoclonal antibodies, ODMS, Protein A/G and Pluronic F127 for optimal Bcl-2 capture with minimal non-specific adsorption. Bcl-2 concentrations were quantified by the resulting resonance frequency shift detected by a custom designed resonator circuit. The target sensitivity for diagnosis and identifying the stage of ovarian cancer was successfully achieved with demonstrated Bcl-2 detection capability of 500 pg/mL. It was also shown that resonance frequency shift increases linearly with increasing Bcl-2 concentration.
Files
bib-4b7b1cbb-fa45-420c-9bf1-6272e72ca52d.txt
Files
(177 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:302d3a13abe0ae2bfad32aac5ad09204
|
177 Bytes | Preview Download |