Published January 1, 2015
| Version v1
Journal article
Open
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
Creators
- 1. Univ Valencia, Dept Elect Engn, Escola Tecn Super Engn, Valencia, Spain
- 2. GANIL, Caen, France
- 3. Polish Acad Sci, Niewodniczanski Inst Nucl Phys, Krakow, Poland
- 4. Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy
- 5. Inst Fis Corpuscular CSIC UV, Valencia, Spain
- 6. Istanbul Sabahattin Zaim Univ, Fac Engn & Nat Sci, Istanbul, Turkey
- 7. Nigde Univ, Fen Edebiyat Falkultesi, Fiz Bolumu, Nigde, Turkey
Description
This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
Files
bib-1d87ec56-bd1e-40d4-8321-450b78606893.txt
Files
(453 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:4d738017bf36039f5cd123cd701280f7
|
453 Bytes | Preview Download |