Published January 1, 2015
| Version v1
Journal article
Open
Experimental investigation of the effects of pipe location on the bearing capacity
Creators
- 1. Osmaniye Korkut Ata Univ, Dept Civil Engn, TR-80000 Osmaniye, Turkey
- 2. Cukurova Univ, Dept Civil Engn, TR-01330 Adana, Turkey
Description
A series of laboratory model tests were conducted to investigate the effects of buried pipes location on the bearing capacity of strip footing in cohesionless soil. The variables examined in the testing program include relative density of the sand, loading rate of tests, burial depths of pipe and horizontal distance of pipe to footing. The test results showed a significant increase in bearing capacities when embedment ratio of pipe and horizontal distance of pipe to footing were increased. Based on the test results, it can be concluded that the location of pipes and relative density of sand are main parameters that affect the bearing capacity of strip footing. However, loading rate has not considerable effect on bearing capacity.
Files
bib-6f368c22-3335-4350-b275-506c040a80a0.txt
Files
(159 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:9ac07270db7f5e801b5fbb22b7aca128
|
159 Bytes | Preview Download |