Published January 1, 2019 | Version v1
Journal article Open

A microfluidic 3D hepatocyte chip for hepatotoxicity testing of nanoparticles

  • 1. Harvard Med Sch, Shriners Hosp, Ctr Engn Med, Massachusetts Gen Hosp, Boston, MA 02114 USA

Description

Aim: To develop a practical microfluidic 3D hepatocyte chip for hepatotoxicity testing of nanoparticles using proof of concept studies providing first results of the potential hepatotoxicity of superparamagnetic iron oxide nanoparticles (SPION) under microfluidic conditions. Methods: A microfluidic 3D hepatocyte chip with three material layers, which contains primary rat hepatocytes, has been fabricated and tested using different concentrations (50, 100 and 200 mu g/ml) of SPION in 3-day (short-term) and 1-week (long-term) cultures. Results: Compared with standard well plates, the hepatocyte chip with flow provided comparable viability and significantly higher liver-specific functions, up to 1 week. In addition, the chip recapitulates the key physiological responses in the hepatotoxicity of SPION. Conclusion: Thus, the developed 3D hepatocyte chip is a robust and highly sensitive platform for investigating hepatotoxicity profiles of nanoparticles.

Files

bib-3bacb97e-2775-4ef1-b2a9-aa4ac719a9a9.txt

Files (178 Bytes)

Name Size Download all
md5:9911b1727599a2c3015910211035d1fa
178 Bytes Preview Download