Published January 1, 2019 | Version v1
Journal article Open

The injection of CO2 to hypersaline geothermal brine: A case study for Tuzla region

  • 1. Izmir Inst Technol, Dept Mat Sci & Engn, TR-35430 Izmir, Turkey
  • 2. Tuzla Geothermal Power Plant, TR-35210 Izmir, Turkey
  • 3. Izmir Inst Technol, Dept Civil Engn, TR-35430 Izmir, Turkey

Description

Scaling is a serious issue for geothermal power plants since it remarkably decreases the harvesting of energy. The reduction of pH by organic acids whose structure is close to CO2 for instance formic acid has been an effective solution for the minimization of scaling. Herein, the effect of CO2 injection on the formation of scaling particularly metal-silicates was investigated for the model case of Tuzla Geothermal Field (TGF) located in the northwest of Turkey. CO2 has an acidic character in aqueous systems because it leads to the formation of carbonic acid. The injection of 20.6 m(3)/s CO2 (approximately 88 ppm) to hypersaline brine of TGF is a promising green approach for both mitigation of scaling by reducing pH from 7.2 to 6.2 at the well-head and the minimization of potential corrosion compared to the use of formic acid (55 ppm).

Files

bib-c0c3537c-ca1d-4c12-8f23-27f303574812.txt

Files (163 Bytes)

Name Size Download all
md5:d462d0bfda5fa5b6bf6c0eaa1fb54642
163 Bytes Preview Download