Yayınlanmış 1 Ocak 2016
| Sürüm v1
Dergi makalesi
Açık
A gamma-distribution convolution model of Tc-99m-MIBI thyroid time-activity curves
Oluşturanlar
- 1. Univ Saskatchewan, Dept Med Imaging, Coll Med, Royal Univ Hosp, 103 Hosp Dr, Saskatoon, SK S7N 0W8, Canada
- 2. Hacettepe Univ, Sch Med, Dept Nucl Med, TR-06100 Ankara, Turkey
Açıklama
Background: The convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) TAC model following bolus intravenous injection is presented and applied to Tc-99m-MIBI data. The GDC model is a convolution of two gamma distribution functions that simultaneously models the distribution and washout kinetics of the radiotracer. The GDC model was fitted to thyroid region of interest (ROI) TAC data from 1 min per frame Tc-99m-MIBI image series for 90 min; GDC models were generated for three patients having left and right thyroid lobe and total thyroid ROIs, and were contrasted with washout-only models, i.e., less complete models. GDC model accuracy was tested using 10 Monte Carlo simulations for each clinical ROI.
Dosyalar
bib-73ae0747-12a0-44d5-8c7c-9e350e171d1d.txt
Dosyalar
(187 Bytes)
| Ad | Boyut | Hepisini indir |
|---|---|---|
|
md5:1f5dd1849e704cdd262e0411bbda56cf
|
187 Bytes | Ön İzleme İndir |