Published January 1, 2009 | Version v1
Journal article Open

A POSITION-INVARIANT CALIBRATION-INDEPENDENT METHOD FOR PERMITTIVITY MEASUREMENTS

  • 1. Microwave Elect Syst Inc MIKES, Dept Syst Engn, TR-06750 Ankara, Turkey

Description

A simple yet powerful calibration-independent method is proposed for complex permittivity extraction of dielectric materials. There are two main features of the method as,as follows: (a) it decreases and uncertainty arising from using a second (extra) sample and (b) it does not require precise location of the sample within its cell (a waveguide or coaxial-line section). The disadvantage of the method is that it may produce some singularity points while extracting the complex permittivity from measurements. We validated the method by calibrated and uncalibrated complex scattering parameter measurements of a poly-vinl-chloride (PVC) sample at X-band (8.2-12.4 GHz). (c) 2009 Wiley Periodicals, Inc. Microwave Opt Technol Lett 51: 1406-1408, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.24364

Files

bib-3cc9f9b6-56bf-474d-9e1a-58a80b7fbc39.txt

Files (171 Bytes)

Name Size Download all
md5:fe4c80aaf4d5b528f0fc842a66d62de2
171 Bytes Preview Download