Published January 1, 2009
| Version v1
Journal article
Open
Noniterative Permittivity Extraction of Lossy Liquid Materials From Reflection Asymmetric Amplitude-Only Microwave Measurements
- 1. Ataturk Univ, Dept Elect & Elect Engn, TR-25240 Erzurum, Turkey
- 2. SUNY Binghamton, Dept Elect & Comp Engn, Binghamton, NY 13902 USA
Description
A very promising amplitude-only microwave method is proposed to noniteratively determine the complex permittivity of lossy materials, which possess at least 10 dB attenuation. It utilizes reflection-only measurements, which in some instances increases the performance of the determination since the accuracy of transmission measurements significantly decreases for high-loss materials. The method is very feasible for industrial-based applications since the implementation of the method requires very simple microwave components or inexpensive microwave instruments. However, the method requires different reflection-only measurements, which in turn necessitates elaborate preparation of the sample holder.
Files
bib-b8a05587-0cea-45d5-b7c2-badc87a7d359.txt
Files
(239 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:467e7cf20808ba6bc2239a37d396c074
|
239 Bytes | Preview Download |