Use of Digital Twin Application Performed with CFDs Analysis in an Underground Mine to Interpret Events During and After a Mine Fire
Creators
- 1. Tumad Medencilik & Sanayi AS, TR-06100 Ankara, Turkiye
- 2. Goa Arge Madencilik & Cevre Teknolojileri Ltd Sti, TR-06100 Ankara, Turkiye
- 3. Diferans Engn & Simulat, TR-35160 Izmir, Turkiye
Description
Fires in underground mines pose significant risks to worker safety. In this study, a digital twin of an underground mine was created, and the heat, gas distribution, and airflow dynamics were investigated during and after the fire using computational fluid dynamics (CFDs) methods at three different locations. While traditional methods did not indicate any problems, the results from the CFDs analyses revealed some important findings. One of the key findings of the study was the change in airflow direction caused by the changing thermodynamic conditions caused by the fire. The digital twin allows us to demonstrate how a fire at any point within the mine can affect the entire mine under these changing thermodynamic conditions. The digital twin enables the real-time monitoring of underground events. Additionally, it facilitates strategic planning to anticipate potential incidents during a fire in an underground mine, allowing for necessary precautions to be implemented.