USE OF DIFFERENT SHAPED STEEL SLIT DAMPERS IN BEAM TO COLUMN CONNECTIONS OF STEEL FRAMES UNDER CYCLING LOADING
- 1. Necmettin Erbakan Univ, Dept Civil Engn, TR-42060 Konya, Turkey
- 2. Selcuk Univ, Dept Civil Engn, TR-42075 Konya, Turkey
Description
Following the Northridge and Kobe earthquakes, extensive research was conducted on the use of various materials and systems that will absorb the earthquake effects within the structure itself in order to improve the behavior of the steel structures under seismic effects. In this study, the use of seismic dampers at beam-column joints of steel-framed structures to prevent damage to the structural members by absorbing the energy of the lateral loads was investigated. Thus, it will be possible for the steel-framed structures to be put into service right after a damaging earthquake by only replacing the dampers attached to the joints as no damage will occur to the beams and columns. For this purpose, as a first step, dampers with ductile behavior were chosen through preliminary tests. Consistent with the results of the preliminary tests, a total of six full-scale corner beam-column joint test specimens were produced. Five specimens were attached various types of dampers m different sizes and one reference specimen was designed with regular end-plate connection.