Improved drowsiness detection in drivers through optimum pairing of EEG features using an optimal EEG channel comparable to a multichannel EEG system
Creators
- 1. Koc Univ, Coll Engn, TR-34450 Istanbul, Turkiye
- 2. Sakarya Univ Appl Sci, Dept Mechatron Engn, TR-54050 Sakarya, Turkiye
- 3. Istanbul Tech Univ, Grad Sch Comp Engn, TR-34469 Istanbul, Turkiye
- 4. Koc Univ, Grad Sch Hlth Sci, TR-34010 Istanbul, Turkiye
- 5. Koc Univ, Res Ctr Translat Med KUTTAM, TR-34010 Istanbul, Turkiye
- 6. Ozyegin Univ, Dept Elect & Elect Engn, TR-34794 Istanbul, Turkiye
Description
Multichannel electroencephalography (EEG)-based drowsiness detection (DD) offers higher coverage but comes with increased computational demands, hardware requirements, and user discomfort, whereas single-channel devices are cost-effective and user-friendly but provide lower coverage. We hypothesized that an optimal channel with optimum paired EEG features could achieve coverage comparable to a multichannel system. Subject-specific, EEG-feature-specific thresholding techniques were introduced to classify 927 EEG epochs, derived from visual-based scoring through image processing of fifty drivers' facial expressions during a 50-min driving simulation, using six individual EEG channels with paired features. Ten normalized EEG features were extracted per epoch using discrete wavelet transform (DWT), and seven thresholding techniques were applied to identify the most consistent method across subjects. Epochs were classified as drowsy or wakeful based on whether their normalized values exceeded or fell below a specific threshold. We then assessed the coverage of each channel by comparing EEG patterns with visual-based scoring. To determine the optimal feature pair for classifying each epoch in alignment with visual-based scoring, 45 feature combinations were evaluated. The pairing of power spectral density (PSD) alpha and PSD theta in channels Frontal4 (F4) and Occipital2 (O2) yielded the highest coverage, achieving 96.1% and 95% with corresponding accuracies of 95.4% and 94.7%, respectively. These results slightly surpassed the coverage achieved using six channels with a single feature, with increases of 1.47% for F4 and 0.32% for O2. Our study demonstrates that an optimal EEG channel with optimum paired EEG features can reduce channels from six to one, lowering computational demands for wearable DD devices.
Files
bib-fe5fdea2-83b5-4708-918c-5e5655d9c6d7.txt
Files
(314 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:7e98858f6242b45b42b04019eb100f61
|
314 Bytes | Preview Download |