Published January 1, 2025 | Version v1
Journal article Open

Effect of Cs-Ion on the corrosion properties of implant materials

  • 1. Gazi Univ, Fac Engn, Dept Chem Engn, TR-06500 Ankara, Turkiye
  • 2. Gazi Univ, Grad Sch Nat & Appl Sci, Dept Adv Technol, TR-06500 Ankara, Turkiye
  • 3. Hlth Sci Univ, Gulhane Med Design & Mfg Res & Applicat Ctr, TR-06010 Ankara, Turkiye
  • 4. Gazi Univ, Fac Technol, Dept Met & Mat Engn, TR-06500 Ankara, Turkiye

Description

Ti-6Al-4V alloy produced by additive manufacturing method and Ti-6Al-4V alloy coated with BN ceramic were analyzed in SRIM/TRIM Monte Carlo Simulation program at 662 keV energy using parameters such as displacement, ionization and phonon, which provide information about radiation damage, using Cs-ion. Postproduction coating thicknesses were determined by taking SEM images of the produced samples. As a result of coating the Ti-6Al-4V alloy with BN, the ion range decreased from the target depth of 3067 & Aring; to 2447 & Aring;. The total amount of damage to the material after coating decreased by approximately 21.1 % ensuring less phonon formation of the implant material exposed to the same gamma energy through the coating process, its negative effect on corrosion resistance, which is important in implant materials, is reduced.

Files

bib-0f020fbc-6d72-4a21-9432-d07c79de1166.txt

Files (183 Bytes)

Name Size Download all
md5:b22688c214c17702be08f8c4b520ee4d
183 Bytes Preview Download