Published January 1, 2025 | Version v1
Journal article Open

Design of a molecularly imprinted polymer sensor modified with saffron-based copper nanoflowers for highly selective and sensitive determination of bortezomib

  • 1. Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06560 Ankara, Turkiye
  • 2. Univ Hlth Sci, Gulhane Fac Pharm, Dept Pharmaceut Bot, Ankara, Turkiye
  • 3. Univ Hlth Sci, Gulhane Fac Pharm, Dept Analyt Chem, Ankara, Turkiye
  • 4. DEVAHolding AS, Res & Dev Ctr, TR-59510 Tekirdag, Turkiye

Description

This work represents the first successful application of a molecularly imprinted polymer (MIP)-based electrochemical sensor for the sensitive and selective determination of the first developed proteasome inhibitor, bortezomib (BOR). BOR is used for the treatment of multiple myeloma, gastrointestinal stromal tumors, and mantle cell lymphoma. It shows its desired effect through the boronate group and can be administered intravenously or subcutaneously. The MIP-based electrochemical sensor design includes the integration of green-synthesized saffron-based copper nanoflowers (CuNFs) from Crocus sativus L. to increase the active surface area and porosity of the glassy carbon electrode (GCE) surface. 2-Acrylamido-2-methyl-1-propanesulfonic acid (AMPS) was selected as the functional monomer along with other MIP components. Detailed characterizations of the developed CuNFs/AMPS/MIP-GCE sensor and CuNFs were performed using scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), energy dispersive X-ray analysis (EDX), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The indirect measurement approach using 5.0 mM [Fe(CN)6]3-/4- solution was used to determine BOR in the linear range of 2.5 x 10-13 M - 2.5 x 10-12 M (0.25-2.5 pM). The LOD and LOQ values of the sensor obtained at the fM level (29 fM and 96.7 fM), which has a linear response in the commercial human serum sample in the same concentration range, emphasize its sensitivity (1.89 x 1013 and 2.14 x 1013 mu A/M for standard solution and serum). The repeatability and reproducibility of the sensor were between 0.87 % and 2.17 %, showing its reliability. The successful performance of the sensor in the presence of metabolites belonging to BOR demonstrates its unique selectivity. The selectivity was demonstrated via relative imprinting factor (IF') values (higher than 3.5) against BOR's metabolites. The stability of the CuNFs/AMPS/MIP-GCE sensor was found to be 5 days.

Files

bib-176405d5-ba13-44cb-a5ef-2f92203bb9a2.txt

Files (273 Bytes)

Name Size Download all
md5:63efd1b013324f172d6b7a08e934c253
273 Bytes Preview Download