Metrisor: A novel diagnostic method for metritis detection in cattle based on machine learning and sensors
Creators
- 1. Firat Univ, Civil Aviat Sch, Dept Airframe & Powerplant Maintenance, Elazig, Turkiye
- 2. Firat Univ, Fac Engineer, Dept Comp Engineer, Elazig, Turkiye
- 3. Firat Univ, Fac Technol, Dept Elect Engineer, Elazig, Turkiye
- 4. Firat Univ, Fac Vet Med, Dept Microbiol, TR-23100 Elazig, Turkiye
- 5. Univ Kastamonu, Fac Vet Med, Dept Obstet & Gynecol, TR-37100 Kastamonu, Turkiye
- 6. Firat Univ, Fac Vet Med, Dept Obstet & Gynecol, TR-23100 Elazig, Turkiye
- 7. Univ Siirt, Fac Vet Med, Dept Obstet & Gynecol, TR-56100 Siirt, Turkiye
- 8. Univ Bingol, Fac Vet Med, Dept Obstet & Gynecol, TR-12100 Bingol, Turkiye
Description
The Metrisor device has been developed using gas sensors for rapid, highly accurate and effective diagnosis of metritis. 513 cattle uteri were collected from abattoirs and swabs were taken for microbiological testing. The Metrisor device was used to measure intrauterine gases. The results showed a bacterial growth rate of 75.75 % in uteri with clinical metritis. In uteri positive for clinical metritis, the most commonly isolated and identified bacteria were Trueperella pyogenes, Fusobacterium necrophorum and Escherichia coli. Measurements taken with Metrisor to determine the presence of metritis in the uterus yielded the most successful results in evaluations of relevant machine learning algorithms. The ICO (Iterative Classifier Optimizer) algorithm achieved 71.22 % accuracy, 64.40 % precision and 71.20 % recall. Experiments were conducted to examine bacterial growth in the uterus and the random forest algorithm produced the most successful results with accuracy, precision and recall values of 78.16 %, 75.30 % and 78.20 % respectively. ICO also showed high performance in experiments to determine bacterial growth in metritis-positive uteri, with accuracy, precision and recall values of 78.97 %, 77.20 % and 79.00 %, respectively. In conclusion, the Metrisor device demonstrated high accuracy in detecting metritis and bacterial growth in uteri and could identify bacteria such as E. coli, S. aureus, coagulase-negative staphylococci, T. pyogenes, Bacillus spp., Clostridium spp. and F. necrophorum with rates up to 80 %. It provides a reliable, rapid and effective means of detecting metritis in animals in the field without the need for laboratory facilities.
Files
bib-fa4dc0d6-281d-4c66-bc22-b5004232c9cd.txt
Files
(295 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:ba3469771166f67116f6615aa0108797
|
295 Bytes | Preview Download |