Development and Fabrication of a Molecularly Imprinted Polymer-Based Electroanalytical Sensor for the Determination of Acyclovir
Oluşturanlar
- 1. Istanbul Tech Univ, Fac Sci & Letters, Dept Chem, TR-34469 Istanbul, Turkiye
- 2. Univ Hlth Sci, Gulhane Fac Pharm, Dept Analyt Chem, TR-06018 Ankara, Turkiye
- 3. Kocaeli Univ, Kocaeli Vocat Sch, Dept Chem & Chem Proc Technol, TR-41140 Kocaeli, Turkiye
- 4. Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06560 Ankara, Turkiye
Açıklama
Acyclovir (ACV), a synthetic nucleoside derivative of purine, is one of the most potent antiviral medications recommended in the specific management of varicella-zoster and herpes simplex viruses. The molecularly imprinted polymer (MIP) was utilized to create an effective and specific electrochemical sensor using a straightforward photopolymerization process to determine ACV. The polymeric thin coating was developed using the template molecule ACV, a functional monomer acrylamide, a basic monomer 2-hydroxyethyl methacrylate, a cross-linker ethylene glycol dimethacrylate, and a photoinitiator 2-hydroxy-2-methyl propiophenone on the exterior of the glassy carbon electrode (GCE). Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, electrochemical impedance spectroscopy, and cyclic voltammetry were employed for the purpose of characterizing the constructed sensor (AM-ACV@MIP/GCE). Differential pulse voltammetry and a 5 mM ferrocyanide/ferricyanide ([Fe(CN)(6)](3-/4-)) redox reagent were used to detect the ACV binding to the specific cavities on MIP. The study involves density functional theory (DFT) calculations, which were conducted to investigate template-functional monomer interactions thoroughly, calculate template-functional monomer interaction energies, and determine the optimal template/functional monomer ratio. DFT calculations were performed using Becke's three-parameter hybrid functional with the Lee-Yang-Parr correlation functional (B3LYP) method and 6-31G(d,p) basis set. The sensor exhibits linear performance throughout the concentration region 1 x 10(-11) to 1 x 10(-10) M, and the limit of detection and limit of quantification were 7.15 x 10(-13) M and 2.38 x 10(-12) M, respectively. For the electrochemical study of ACV, the sensor demonstrated high accuracy, precision, robustness, and a short detection time. Furthermore, the developed electrochemical sensor exhibited exceptional recovery in tablet dosage form and commercial human blood samples, with recoveries of 99.40 and 100.44%, respectively. The findings showed that the AM-ACV@MIP/GCE sensor would effectively be used to directly assess pharmaceuticals from actual specimens and would particularly detect ACV compared to structurally similar pharmaceutical compounds.
Dosyalar
bib-5ea41ab1-c63d-48c3-a2ca-a6fa85f18a97.txt
Dosyalar
(241 Bytes)
| Ad | Boyut | Hepisini indir |
|---|---|---|
|
md5:fecac58e8570bdaf01ab284aa84e7295
|
241 Bytes | Ön İzleme İndir |