Investigation of the geometry effect on air-demand ratio in conduits with a sluice gate
- 1. Firat Univ, Dept Civil Engn, Elazig, Turkiye
- 2. Eskisehir Tech Univ, Dept Civil Engn, Eskisehir, Turkiye
- 3. Munzur Univ, Dept Civil Engn, Tunceli, Turkiye
Description
Gated conduits involve high-velocity air-water flow. When the studies on the gated conduits are examined, it is determined that the air-demand ratio changed according to the hydraulic and geometric parameters. However, no study has investigated the effect of the cross-sectional geometry of high-head conduits with a sluice gate on the air-demand ratio. In this study, the effect of conduit cross-sectional geometry on the air-demand ratio is examined. Results indicate that conduit cross-sectional geometry is an important effect on the air-demand ratio, especially at 10% and 15% gate opening rates. It is seen that the effect of the conduit geometry on the air-demand ratio decreases at 20%, and greater gate opening rates. Moreover, a formula for the air-demand ratio is presented relating the air-demand ratio to the gate opening rate, Froude number, hydraulic radius, and conduit length was presented for estimating the air-demand ratio.
Files
bib-5209fa6a-91e6-4bba-b9fc-922e43ef7729.txt
Files
(228 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:3b38f0b770497b81cb189b2f072ffcf3
|
228 Bytes | Preview Download |