Published January 1, 2023
| Version v1
Journal article
Open
A Commercially Available 2-aminoanthracene Fluorescent Probe for Rapid and Sensitive Detection of Hypochlorite in 100% Buffer Solution and its Application in Complex Water Samples
Creators
- 1. Natl Metrol Inst TUBITAK UME, Organ Chem Lab, Chem Grp, TR-41470 Gebze, Kocaeli, Turkiye
Description
Hypochlorite (ClO-), a crucial chemical in the living organism, engages in various physiological activities. However, high amounts of ClO- result in oxidative damage. In this work, a commercially available 2-aminoanthracene (AA) was used to detect ClO-. AA demonstrated distinct properties such as superior selectivity and rapid response (< 30 s) with a low detection limit (140 nM) towards ClO- in 100% buffer solution. Furthermore, the probe exhibited a notable achievement by effectively identifying the presence of ClO- in complicated water samples. In conclusion, AA offers an easy-to-use and accurate method for quantifying ClO- in complex water samples.
Files
bib-7f8306ac-7c00-4d69-ad27-4f6bf16a8cda.txt
Files
(229 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:426686e9d78b1c24d426d6dbd67197f1
|
229 Bytes | Preview Download |