Published January 1, 2022
| Version v1
Journal article
Open
An Electrochemical Biosensing Platform for the SARS-CoV-2 Spike Antibody Detection Based on the Functionalised SARS-CoV-2 Spike Antigen Modified Electrode
Creators
- 1. TUBITAK UME, Natl Metrol Inst, Sci & Technol Res Council Turkey, Electrochem Lab,Chem Grp, TR-41470 Kocaeli, Turkey
Description
We developed an electrochemical biosensing platform using gold-clusters, cysteamine, the spike protein of the severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) antigen and bovine serum albumin on a glassy carbon electrode able to determine the SARS-CoV-2 spike antibody. The developed biosensor could detect 9.3 ag/mL of the SARS-CoV-2 spike antibody in synthetic media in 20 min in a linear range from 0.1 fg/mL to 10.0 pg/mL. The developed method demonstrated good selectivity in the presence of spike antigens from other viruses. Clinical samples consisting of gargle and mouthwash liquids were analyzed with both RT-PCR and the developed biosensor system to reveal the sensitivity and specificity of the proposed method. Moreover, the developed method was compared with the lateral flow immunoassay method in terms of sensitivity.
Files
bib-1d7e5861-b649-49f8-806b-a3cb8f9b1599.txt
Files
(209 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:824ee8d2047d4c7c4fd7ea00cbf827c6
|
209 Bytes | Preview Download |