Published January 1, 2010
| Version v1
Conference paper
Open
VOC GAS LEAK DETECTION USING PYRO-ELECTRIC INFRARED SENSORS
- 1. Bilkent Univ, Dept Elect & Elect Eng, Ankara, Turkey
- 2. ASELSAN Inc, Ankara, Turkey
- 3. Univ Minnesota, Dept Comp Sci & Engn, Minneapolis, MN USA
Description
In this paper, we propose a novel method for detecting and monitoring Volatile Organic Compounds (VOC) gas leaks by using a Pyro-electric (or Passive) Infrared (PIR) sensor whose spectral range intersects with the absorption bands of VOC gases. A continuous time analog signal is obtained from the PIR sensor. This signal is discretized and analyzed in real time. Feature parameters are extracted in wavelet domain and classified using a Markov Model (MM) based classifier. Experimental results are presented.
Files
bib-7f748191-5c97-4cae-9e85-689e372a15fe.txt
Files
(193 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:9a83a10c8a000a9891048a62254c5fa0
|
193 Bytes | Preview Download |