Published January 1, 2022
| Version v1
Journal article
Open
The calculation of self-shielding correction factors for large samples in Am-241-Be isotopic neutron source
Creators
- 1. Bursa Uludag Univ, Phys Dept, Fac Arts & Sci, Goriikle Campus, TR-16059 Bursa, Turkey
Description
In the present study, it is aimed to calculate neutron self-shielding correction factors for cylinder sample geometry using different methods in the literature in the application of k(0)-NAA standardization method with Am-241-Be isotopic neutron source. These correction factors are important in calculating the accurate concentration values for large samples with a high neutron absorption cross-section in the application of the k(0)-NAA method. In order to see the validity of the applied theoretical and experimental methods, the obtained concentration values are given comparatively with respect to the known Mn concentrations. The mean concentration difference ranges from-3.4% to-9.7%. The thermal neutron self-shielding correction depends on all elements in the sample that absorb thermal neutrons. In k(0)-NAA applications with large samples, although timeconsuming, it is recommended to use the experimental methods after calculating the necessary parameters with the help of samples with known composition.
Files
bib-75d71013-a420-40f7-9157-9671304fab0f.txt
Files
(170 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:3fdf8a5ca5af8bac64e222ae1701bbd9
|
170 Bytes | Preview Download |