Published January 1, 2011 | Version v1
Journal article Open

Photoelectrocatalytic determination of NADH in a flow injection system with electropolymerized methylene blue

  • 1. Canakkale Onsekiz Mart Univ, Sci & Art Fac, Dept Chem, TR-17100 Canakkale, Turkey
  • 2. Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Turkey
  • 3. Univ Babes Bolyai, Dept Environm Phys Chem & Engn, Cluj Napoca 400294, Romania

Description

It was firstly described that a glassy carbon electrode electropolymerized with methylene blue shows an efficient photoelectrocatalytic activity towards NADH oxidation in a phosphate buffer solution (pH 7.0). In order to perform the photoelectrocatalytic determination of NADH in a flow injection analysis (FIA) system, a home-made flow electrochemical cell with a suitable transparent window for the irradiation of the electrode surface was constructed. The currents obtained from the photoamperometric measurements in the FIA system at optimum conditions (flow rate of carrier solution, 1.3 mL min(-1): transmission tubing length, 10 cm; injection volume, 100 mu L; and constant applied potential, +150 mV vs. Ag/AgCl) were linearly dependent on the NADH concentration and linear calibration curves were obtained in the range of 1.0 x 10(-7)-2.0 x 10(-4) M. The detection limit was found to be 4.0 x 10(-8) M for photoamperometric determination of NADH. (C) 2010 Elsevier Ltd. All rights reserved.

Files

bib-c8054178-0227-470e-8248-70485e90c8f1.txt

Files (240 Bytes)

Name Size Download all
md5:a7feba263bdda00aef9104cd65bf148a
240 Bytes Preview Download