Published January 1, 2011
| Version v1
Journal article
Open
Performance Comparison of Thermal-Sprayed Coatings for Ductile Iron Pipe
- 1. Istanbul Water & Sewerage Adm, TR-34406 Istanbul, Turkey
- 2. Sakarya Univ, Dept Met & Mat Engn, TR-54187 Sakarya, Turkey
- 3. Sakarya Univ, Fac Engn, TR-54187 Sakarya, Turkey
- 4. Fatih Sultan Mehmet Vakif Univ, Dept Architectural Engn, TR-34406 Istanbul, Turkey
Description
In several countries, Zn and Zn/Al 85/15 coatings applied by thermal spray are used to protect underground ductile iron (DI) pipe against soil corrosion. In this study, DI pipe samples were coated with Zn and Zn/Al 85/15. Test results showed that Zn/Al 85/15 coatings have better corrosion resistance than Zn coatings and the annealing oxide on DI pipe acts as a good corrosion-resistant protective layer.
Files
bib-80516497-9d44-4750-8480-60928c2266d7.txt
Files
(186 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:c0c0db77d21e6e22ca071e4a83341c3a
|