Published January 1, 2013 | Version v1
Conference paper Open

A Stator Voltage Oriented Doubly Fed Induction Generator Control Method with a Disturbance Observer

  • 1. Istanbul Tech Univ, TR-80626 Istanbul, Turkey
  • 2. Sabanci Univ, Mechatron Engn, Istanbul, Turkey

Description

Due to their robustness and cost effectiveness, double fed induction generator (DFIG) based wind turbines are becoming very popular in wind energy conversion systems. Robustness of any implemented control structure can easily be lost due to nonlinearities, variations in the DFIG parameters and network voltage failures. In this study, machine parameter dependent terms will be estimated with the first order low pass filter disturbance observer, and stator voltage orientation will be applied in the experimental test bed. DSPACE DS1103 platform is used as a digital controller.

Files

bib-df86bdfc-f9c1-4dd6-acef-824fcd98048d.txt

Files (180 Bytes)

Name Size Download all
md5:c25b3d53e944fd6467238aab3ed1ff14
180 Bytes Preview Download