Nonenzymatic glucose sensor based on poly(3,4-ethylene dioxythiophene)/electroreduced graphene oxide modified gold electrode

  • 1. Ataturk Univ, Dept Nanosci & Nanoengn, Nanomat Sci, TR-25240 Erzurum, Turkey

Description

In this study, a nonenzymatic glucose sensor based on a Au electrode was modified using layered poly(3,4-ethylene dioxythiophene) (PEDOT) and electroreduced graphene oxide (ERGO). The modified electrode was characterized by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). The electrochemical performance of the electrode material was evaluated to assess its use in glucose sensor applications. In addition, the effect of layer numbers of the layered composite on glucose activity was investigated. The monolayer PEDOT-ERGO nanocomposite exhibited high current density, high sensitivity, and low detection limit of approximately 5 mA cm(-2), 696.9 mu A mM(-1) cm(-2), and 0.12 mu M, respectively. Moreover, an electrode interference test was conducted in the presence of various interfering species such as ascorbic acid, uric acid, dopamine, and H2O2, revealing excellent selectivity of the nonenzymatic glucose sensor. Thus, the PEDOT-ERGO modified Au electrode could be utilized as a promising nonenzymatic glucose biosensor.