A Reference System for Measuring High-DC Voltage Based on Voltage References
Creators
- 1. Tubitak Ulusal Metrol Enstitusu, TR-41470 Gebze, Turkey
- 2. Ctr Metrol & Accreditat, Espoo 02151, Finland
Description
In this paper, a 20-kV voltage reference based on shunt type bandgap references has been built and characterized. Compared with earlier designs based on temperature compensated Zener diodes, the main advantages of the new design are much lower uncertainty and dynamic impedance, combined with lower cost. The temperature coefficient of shunt references has been compensated using selected traditional Zener diodes. A commercial four quadrant current source has been used for the stabilization of the leakage current. The measurement system has stable output over a wide range of operating current and ambient temperature, and it is insensitive to effects due to leakage currents. The reference has a maximum voltage of 20 kV, and it is expandable to higher voltages. The estimated measurement uncertainty of the system is less than 5 mu V/V.