Yayınlanmış 1 Ocak 2017 | Sürüm v1
Konferans bildirisi Açık

Wind Power Potential Assessment of Kano, Nigeria

  • 1. Selcuk Univ, Dept Elect & Elect Engn, Konya, Turkey
  • 2. Calif State Polytech Univ Pomona, Dept Elect & Comp Engn, Pomona, CA 91768 USA
  • 3. Ahmadu Bello Univ, Dept Elect & Comp Engn, Zaria, Nigeria
  • 4. Univ Northern Iowa, Dept Technol, Cedar Falls, IA 50614 USA

Açıklama

This paper investigates wind power potential assessment of Kano, located at North-Western region of Nigeria where the wind is highly variable and energy demand is high. Weibull probability density function is used to analyze Kano wind speed data obtained from Nigerian Meteorological Agency (NIMET). The analysis shows that average monthly wind power density of Kano varies from 213.913 W/m(2) to 735.925 W/m(2). The study also revealed that Kano has seasonal average wind power density of 471.941 W/m(2) for dry seasons and 461.450 W/m(2) for rainy seasons. The annual power density ranges from 297.481 W/m(2) to 830.801 W/m(2). The most probable wind speed (V-mp) and maximum energy carrying wind speed (V-maxE) monthly and annually values are found for dry and rainy seasons. Seasonal conditions are considered as well. All of the results show that Kano clearly falls under the highest class of 7 according to wind power density classes.

Dosyalar

bib-922f7c7a-0232-46c5-9f9b-79a31457212f.txt

Dosyalar (148 Bytes)

Ad Boyut Hepisini indir
md5:18860dc44986a5d42a68e05f4eee055c
148 Bytes Ön İzleme İndir